{"database": "openregs", "table": "federal_register", "rows": [["2017-12078", "Airworthiness Directives; Pratt & Whitney Turbofan Engines", "Rule", "We are superseding Airworthiness Directive (AD) 2014-05-32 for all Pratt & Whitney (PW) PW2037, PW2037D, PW2037M, PW2040, PW2040D, PW2043, PW2143, PW2643, and F117-PW-100 turbofan engines. AD 2014-05-32 required one-time eddy current inspection (ECI) of affected engines with certain diffuser and high-pressure turbine (HPT) cases installed. AD 2014-05-32 also required a fluorescent-penetrant inspection (FPI) of the diffuser case rear flange and the HPT case front flange. This AD requires additional repetitive, on-wing ECI inspections. This AD was prompted by the manufacturer determining through analysis that the inspections required by AD 2014-05-32 are not adequate to maintain safety for certain diffuser cases. We are issuing this AD to correct the unsafe condition on these products.", "2017-06-13", 2017, 6, "https://www.federalregister.gov/documents/2017/06/13/2017-12078/airworthiness-directives-pratt-and-whitney-turbofan-engines", "https://www.govinfo.gov/content/pkg/FR-2017-06-13/pdf/2017-12078.pdf", "Transportation Department; Federal Aviation Administration", "492,159", "We are superseding Airworthiness Directive (AD) 2014-05-32 for all Pratt & Whitney (PW) PW2037, PW2037D, PW2037M, PW2040, PW2040D, PW2043, PW2143, PW2643, and F117-PW-100 turbofan engines. AD 2014-05-32 required one-time eddy current inspection (ECI)...", null]], "columns": ["document_number", "title", "type", "abstract", "publication_date", "pub_year", "pub_month", "html_url", "pdf_url", "agency_names", "agency_ids", "excerpts", "regulation_id_numbers"], "primary_keys": ["document_number"], "primary_key_values": ["2017-12078"], "units": {}, "query_ms": 5.950315855443478, "source": "Federal Register API & Regulations.gov API", "source_url": "https://www.federalregister.gov/developers/api/v1", "license": "Public Domain (U.S. Government data)", "license_url": "https://www.regulations.gov/faq"}