| 46:46:2.0.1.2.20.1.1.1 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.01 | Subpart 63.01—General Provisions | § 63.01-1 Purpose. | USCG | This part specifies the minimum requirements for safety for each automatic auxiliary boiler, including its design, construction, testing, and operation. | ||||
| 46:46:2.0.1.2.20.1.1.2 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.01 | Subpart 63.01—General Provisions | § 63.01-3 Scope and applicability. | USCG | [CGD 88-057, 55 FR 24238, June 15, 1990, as amended by USCG-2002-13058, 67 FR 61278, Sept. 30, 2002; USCG-2004-18884, 69 FR 58346, Sept. 30, 2004; USCG-2020-0634, 89 FR 50196, June 12, 2024] | (a) This part contains the requirements for automatic auxiliary boilers, including their controls, control system components, electrical devices, safety devices, and accessories. Types of automatic auxiliary boilers which are covered include large and small automatic auxiliary boilers, automatic heating boilers, automatic waste heat boilers, donkey boilers, miniature boilers, electric boilers, fired thermal fluid heaters, automatic incinerators, and electric hot water supply boilers. Automatic auxiliary boilers are classified by their service, control systems, pressure and temperature boundaries, heat input ratings, and firing mediums as follows: (1) Automatic auxiliary boilers listed in table 1 to § 54.01-5 of this subchapter which reference this part for regulation of their automatic controls. (2) Automatic control systems for automatic auxiliary boilers having a heat input rating of less than 12,500,000 Btu/hr. (3.66 megawatts). (3) Electric hot water supply boilers (heaters) containing electric heating elements rated at 600 volts or less. (4) Exhaust gas boilers, and their controls and accessories used to heat water and/or generate steam. (5) Incinerators (and their control systems) used for the generation of steam and/or oxidation of ordinary waste materials and garbage. This part also includes incinerators which serve as automatic auxiliary boilers. (6) Fired thermal fluid heaters and their controls. (b) Automatic boilers having heat input ratings of 12,500,000 Btu/hr. (3.66 megawatts) and above must meet the requirements of part 52 of this subchapter. Their control systems must meet the requirements of part 62 of this subchapter. | |||
| 46:46:2.0.1.2.20.2.1.1 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.05 | Subpart 63.05—Reference Specifications | § 63.05-1 Incorporation by reference. | USCG | [USCG-2020-0634, 89 FR 50196, June 12, 2024] | Certain material is incorporated by reference into this part with the approval of the Director of the Federal Register under 5 U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than that specified in this section, the Coast Guard must publish a document in the Federal Register and the material must be available to the public. All approved incorporation by reference (IBR) material is available for inspection at the U.S. Coast Guard and the National Archives and Records Administration (NARA). Contact U.S. Coast Guard Headquarters at: Commandant (CG-ENG), Attn: Office of Design and Engineering Standards, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE, Washington, DC 20593-7509; phone (202) 372-1375; email typeapproval@uscg.mil . For information on the availability of this material at NARA, visit www.archives.gov/federal-register/cfr/ibr-locations or email fr.inspection@nara.gov . The material may be obtained from the following sources: (a) American Society of Mechanical Engineers ( ASME ), Two Park Avenue, New York, NY 10016-5990; 800-843-2763; CustomerCare@asme.org ; www.asme.org . (1) ASME CSD-1-2018, Controls and Safety Devices for Automatically Fired Boilers, issued October 12, 2018 (“ASME CSD-1”); IBR approved for §§ 63.10-1(b); 63.15-1(b); 63.20-1. (2) [Reserved] (b) ASTM International (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; service@astm.org ; www.astm.org . (1) ASTM F1323-14, Standard Specification for Shipboard Incinerators, approved November 1, 2014 (2001) (“ASTM F1323”); IBR approved for § 63.25-9(a). (2) [Reserved] (c) Canadian Standards Association (CSA), CSA Group, 5060 Spectrum Way, Suite 100, Mississauga, ON, Canada L4W 5N6; 416-474-2233; techsupport@csagroup.org ; https://shop.csa.ca . (1) ANSI Z21.22-2015/CSA 4.4-2015, Relief valves for hot water systems, July 2015 (“ANSI Z21.22”); IBR approved for § 63.25-3(a). (2) [Reserved] CSA material also available from the American National Standar… | |||
| 46:46:2.0.1.2.20.3.1.1 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.10 | Subpart 63.10—Miscellaneous Submittals | § 63.10-1 Test procedures and certification report. | USCG | [USCG-2020-0634, 89 FR 50197, June 12, 2024] | Two copies of the items listed below must be provided, if submitted in printed format, to the Commanding Officer, Marine Safety Center, U.S. Coast Guard, 2703 Martin Luther King Jr. Ave SE, Washington, DC 20593. Alternatively, one copy may be transmitted by email to the Commanding Officer (MSC), at msc@uscg.mil . Information for submitting documents electronically can be found at www.uscg.mil/HQ/MSC . (a) Detailed instructions for operationally testing each automatic auxiliary boiler, its controls, and safety devices. (b) A certification report for each automatic auxiliary boiler that: (1) Meets paragraph CG-510 of ASME CSD-1 (incorporated by reference, see § 63.05-1); and (2) Certifies that each automatic auxiliary boiler, its controls, and safety devices comply with the additional requirements of this part. | |||
| 46:46:2.0.1.2.20.4.1.1 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.15 | Subpart 63.15—General Requirements | § 63.15-1 General. | USCG | [CGD 88-057, 55 FR 24238, June 15, 1990, as amended by USCG-2003-16630, 73 FR 65191, Oct. 31, 2008] | (a) Each automatic auxiliary boiler must be designed and constructed for its intended service according to the requirements of the parts referenced in table 1 to § 54.01-5 of this subchapter. (b) Controls and safety devices for automatic auxiliary boilers must meet the applicable requirements of ASME CSD-1 (incorporated by reference, see § 63.05-1), except Paragraph CG-310. (c) All devices and components of an automatic auxiliary boiler must satisfactorily operate within the marine environment. The boiler must satisfactorily operate with a momentary roll of 30°, a list of 15°, and a permanent trim of 5° with it installed in a position as specified by the manufacturer. (d) An electrical control used to shut down the automatic auxiliary boiler must be installed in accordance with § 58.01-25 of this subchapter. This device must stop the fuel supply to the fuel burning equipment. (e) Mercury tube actuated controls are prohibited from being installed and used on automatic auxiliary boilers. | |||
| 46:46:2.0.1.2.20.4.1.2 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.15 | Subpart 63.15—General Requirements | § 63.15-3 Fuel system. | USCG | [CGD 88-057, 55 FR 24238, June 15, 1990, as amended by USCG-2003-16630, 73 FR 65191, Oct. 31, 2008] | (a) Firing of an automatic auxiliary boiler by natural gas is prohibited unless specifically approved by the Marine Safety Center. (b) Heated heavy fuel oil may be used provided the heaters are equipped with a high temperature limiting device that shuts off the heating source at a temperature below the flashpoint of the oil and is manually reset. When a thermostatically-controlled electric oil heater and a level device is used, it must meet the requirements of subpart 111.85 of this chapter. An auxiliary boiler may be safely ignited from the cold condition using unheated diesel or light fuel oil and subsequently shifted to heated heavy fuel. (c) The fuel oil service pump and its piping system must be designed in accordance with § 56.50-65 of this subchapter. All materials must meet the requirements of subpart 56.60 of this subchapter. The use of cast iron or malleable iron is prohibited. (d) The fuel oil service system (including the pump) must meet the pressure classification and design criteria found in table 1 to § 56.04-2 of this subchapter. (e) When properly selected for the intended service, fuel pumps meeting the performance and test requirements of UL 343 (incorporated by reference, see § 63.05-1) meet the requirements of this section. | |||
| 46:46:2.0.1.2.20.4.1.3 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.15 | Subpart 63.15—General Requirements | § 63.15-5 Strainers. | USCG | [CGD 88-057, 55 FR 24238, June 15, 1990, as amended by USCG-2003-16630, 73 FR 65191, Oct. 31, 2008] | (a) Strainers must be installed in the fuel supply line. Each strainer must be self-cleaning, fitted with a bypass, or be capable of being cleaned without interrupting the fuel oil supply. (b) The strainer must not allow a quantity of air to be trapped inside which would affect the rate of fuel flow to the burner or reduce the effective area of the straining element. (c) The strainer must meet the requirements for strainers found in UL 296 (incorporated by reference, see § 63.05-1) and the requirements for fluid conditioner fittings found in § 56.15-5 of this subchapter. | |||
| 46:46:2.0.1.2.20.4.1.4 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.15 | Subpart 63.15—General Requirements | § 63.15-7 Alarms. | USCG | (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system. (b) Means must be provided to silence the audible alarm. The visible indicators must require manual reset. (c) For steam boilers, operation of the lower low water cutoff must automatically sound an audible alarm. A visual indicator must indicate that the shutdown was caused by low water. (d) For a periodically unattended machinery space, the auxiliary boiler trip alarm required by table 1 to § 62.35-50 of this subchapter satisfies the requirements for the audible alarms specified in this section. | ||||
| 46:46:2.0.1.2.20.4.1.5 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.15 | Subpart 63.15—General Requirements | § 63.15-9 Inspections and tests. | USCG | All automatic auxiliary boilers must be inspected and tested in accordance with the requirements of part 61 of this subchapter. | ||||
| 46:46:2.0.1.2.20.5.1.1 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.20 | Subpart 63.20—Additional Control System Requirements | § 63.20-1 Specific control system requirements. | USCG | [CGD 88-057, 55 FR 24238, June 15, 1990, as amended by USCG-2003-16630, 73 FR 65191, Oct. 31, 2008] | In addition to the requirements found in ASME CSD-1 (incorporated by reference; see § 63.05-1), the following requirements apply for specific control systems: (a) Primary safety control system. Following emergency safety trip control operation, the air flow to the boiler must not automatically increase. For this condition, postpurge must be accomplished manually. (b) Combustion control system. A low fire interlock must ensure low fire start when variable firing rates are used. (c) Water level controls and low water cutoff controls. Water level controls must be constructed and located to minimize the effects of vessel roll and pitch. Float chamber low water cutoff controls using stuffing boxes to transmit the motion of the float from the chamber to the external switches are prohibited. No outlet connection other than pressure controls, water columns, drains, and steam gages may be installed on the float chamber or on the pipes connecting the float chamber to the boiler. The water inlet valve must not feed water into the boiler through the float chamber. The boiler feed piping must comply with the applicable requirements of § 56.50-30 of this subchapter. | |||
| 46:46:2.0.1.2.20.6.1.1 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.25 | Subpart 63.25—Requirements for Specific Types of Automatic Auxiliary Boilers | § 63.25-1 Small automatic auxiliary boilers. | USCG | [CGD 88-057, 55 FR 24238, June 15, 1990, as amended by USCG-2003-16630, 73 FR 65191, Oct. 31, 2008] | Small automatic auxiliary boilers defined as having heat-input ratings of 400,000 Btu/hr. or less (117 kilowatts or less) must also meet the following requirements. (a) Small automatic auxiliary boilers must be equipped with a visual indicator which indicates when the low water cutoff has activated. (b) A prepurge period of a sufficient duration to ensure at least four changes of air in the combustion chamber and stack, but not less than 15 seconds must be provided. Ignition must occur only before or simultaneously with the opening of the fuel oil valve. | |||
| 46:46:2.0.1.2.20.6.1.2 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.25 | Subpart 63.25—Requirements for Specific Types of Automatic Auxiliary Boilers | § 63.25-3 Electric hot water supply boilers. | USCG | [CGD 88-057, 55 FR 24238, June 15, 1990, as amended by CGD 95-028, 62 FR 51202, Sept. 30, 1997; USCG-2003-16630, 73 FR 65191, Oct. 31, 2008; USCG-2020-0634, 89 FR 50198, June 12, 2024] | (a) Electric hot water supply boilers that have a capacity not greater than 454 liters (120 U.S. gallons), a heat input rate not greater than 200,000 Btu/hr. (58.6 kilowatts), meet the requirements of UL 174 or UL 1453 (both incorporated by reference, see § 63.05-1), and are protected by the relief device(s) required in § 53.05-2 of this subchapter do not have to meet any other requirements of this section except the periodic testing required by paragraph (j) of this section. Electric hot water supply boilers that meet the requirements of UL 174 may have temperature-pressure relief valves that meet the requirements of ANSI Z21.22 (incorporated by reference, see 4 § 63.05-1) in lieu of subpart 53.05 of this subchapter. (b) Each hot water supply boiler must be constructed in accordance with the applicable requirements of part 52 or part 53 of this subchapter. (c) Branch circuit conductors for hot water supply boilers which have a capacity not greater than 454 liters (120 U.S. gallons) must have a current carrying capacity of not less than 125 percent of the current rating of the appliance. Branch circuit conductors for hot water supply boilers with capacities of more than 454 liters (120 U.S. gallons) must have a current carrying capacity of not less than 100 percent of the current rating of the appliance. Wiring materials and methods must comply with subpart 111.60 of this chapter. A hot water supply boiler having a current rating of more than 48 amperes and employing resistance type heating elements must have the heating elements on subdivided circuits. Each subdivided load, except for an electric hot water supply boiler employing a resistance type immersion electric heating element, must not exceed 48 amperes, and it must be protected at not more than 60 amperes. An electric hot water supply boiler employing a resistance type immersion electric heating element may be subdivided into circuits not exceeding 120 amperes and protected at not more than 150 amperes. Overcurrent protection devices must comply with su… | |||
| 46:46:2.0.1.2.20.6.1.3 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.25 | Subpart 63.25—Requirements for Specific Types of Automatic Auxiliary Boilers | § 63.25-5 Fired thermal fluid heaters. | USCG | [CGD 88-057, 55 FR 24238, June 15, 1990, as amended by USCG-2020-0634, 89 FR 50198, June 12, 2024] | (a) Construction. Fired thermal fluid heaters must meet the requirements of part 52 of this subchapter, as applicable. (b) Controls. Fired thermal fluid heaters must have a low fluid level cutout device or a low flow device. When the rate of fluid flow through the heating coils is insufficient to ensure proper heat transfer, the device must cut off the fuel supply to the burner. If the fluid temperature exceeds the designed maximum operating temperature, a high temperature limit device must cut off the fuel supply to the burner. These devices must be of the manual reset type. | |||
| 46:46:2.0.1.2.20.6.1.4 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.25 | Subpart 63.25—Requirements for Specific Types of Automatic Auxiliary Boilers | § 63.25-7 Exhaust gas boilers. | USCG | [CGD 88-057, 55 FR 24237, June 15, 1990, as amended by USCG-2020-0634, 89 FR 50198, June 12, 2024] | (a) Construction. An auxiliary exhaust gas boiler must meet the applicable construction requirements of part 52 or part 53 of this subchapter as determined from table 1 to § 54.01-5 of this subchapter. (b) Controls. Each drum type exhaust gas steam boiler must have a feed water control system. The system must automatically supply the required amount of feed water and maintain it at the proper level. For boilers without a fixed water level, the control system must supply the feed water at a rate sufficient to ensure proper heat transfer. The system must adequately fill the boiler when cold. (c) Alarms. When a condition arises which results in inadequate heat transfer, a high temperature alarm or low flow alarm must be activated. An audible alarm must automatically sound, and a visual indicator must indicate when the fluid temperature exceeds the maximum operating temperature or when the fluid/steam flowing through the heat exchanger is insufficient to ensure proper heat transfer. Additionally, an audible alarm must automatically sound, and a visual indicator must indicate when a soot fire is present in the exhaust gas boiler's uptake. | |||
| 46:46:2.0.1.2.20.6.1.5 | 46 | Shipping | I | F | 63 | PART 63—AUTOMATIC AUXILIARY BOILERS | 63.25 | Subpart 63.25—Requirements for Specific Types of Automatic Auxiliary Boilers | § 63.25-9 Incinerators. | USCG | [USCG-2020-0634, 89 FR 50198, June 12, 2024] | (a) General. (1) Incinerators installed on or after March 26, 1998, must meet the requirements of IMO MEPC.76(40) (incorporated by reference; see § 63.05-1). Incinerators in compliance with ISO 13617 (incorporated by reference; see § 63.05-1), are considered to meet IMO MEPC.76(40). Incinerators in compliance with both ASTM F1323 (incorporated by reference; see § 63.05-1) and Annexes A1-A3 of IMO MEPC.76(40) are considered to meet IMO MEPC.76(40). (2) An application for type approval of shipboard incinerators must be sent to the Commanding Officer, Marine Safety Center, U.S. Coast Guard, 2703 Martin Luther King Jr. Ave. SE, Washington, DC 20593, or it may be transmitted by email to the Commanding Officer (MSC), at msc@uscg.mil . (b) Testing. Before type approval is granted, the manufacturer must submit evidence that tests have been conducted by an independent third party acceptable to the Commandant (CG-ENG). Testing may be conducted at the manufacturer's facility. The independent third party must: (1) Have experienced and qualified personnel to conduct the inspections and tests required by this section; (2) Have documented proof of the qualifications to perform the inspections and tests required by this section; and (3) Not be owned or controlled by a manufacturer, supplier, or vendor of shipboard incinerators. (c) Prohibited substances. Shipboard incineration of the following substances is prohibited: (1) Annex I, II, and III cargo residues of IMO MARPOL 73/78 (incorporated by reference; see § 63.05-1) and related contaminated packing materials. (2) Polychlorinated biphenyls (PCBs). (3) Garbage, as defined in Annex V of IMO MARPOL 73/78, containing more than traces of heavy metals. (4) Refined petroleum products containing halogen compounds. (d) Operating manual. Each ship with an incinerator subject to this rule must possess a manufacturer's operating manual, which must specify how to operate the incinerator within the limits described in Annex A1.5 of IMO MEPC.76(40). (e) Training. Each… |
Advanced export
JSON shape: default, array, newline-delimited, object
CREATE TABLE cfr_sections (
section_id TEXT PRIMARY KEY,
title_number INTEGER,
title_name TEXT,
chapter TEXT,
subchapter TEXT,
part_number TEXT,
part_name TEXT,
subpart TEXT,
subpart_name TEXT,
section_number TEXT,
section_heading TEXT,
agency TEXT,
authority TEXT,
source_citation TEXT,
amendment_citations TEXT,
full_text TEXT
);
CREATE INDEX idx_cfr_title ON cfr_sections(title_number);
CREATE INDEX idx_cfr_part ON cfr_sections(part_number);
CREATE INDEX idx_cfr_agency ON cfr_sections(agency);