| section_id ▼ | title_number | title_name | chapter | subchapter | part_number | part_name | subpart | subpart_name | section_number | section_heading | agency | authority | source_citation | amendment_citations | full_text |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 24:24:5.1.2.1.5.1.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | A | Subpart A—General | § 3285.1 Administration. | HUD | (a) Scope. These Model Installation Standards provide minimum requirements for the initial installation of new manufactured homes, in accordance with section 605 of the Act (42 U.S.C. 5404). The Model Installation Standards are one component of the Manufactured Home Installation Program in Part 3286 of this chapter, upon effect, and serve as the basis for developing the manufacturers' installation instructions required by § 3285.2 of this subpart. The manufacturer's installation instructions, including specific methods for performing a specific operation or assembly, will be deemed to comply with these Model Installation Standards, provided they meet or exceed the minimum requirements of these Model Installation Standards and do not take the home out of compliance with the Manufactured Home Construction and Safety Standards (24 CFR part 3280). Work necessary to join all sections of a multi-section home specifically identified in Subparts G, H, and I of this part, or work associated with connecting exterior lights, chain-hung light fixtures, or ceiling-suspended fans, as specifically identified in Subpart I, is not considered assembly or construction of the home, although the design of those elements of a manufactured home must comply with the Manufactured Home Construction and Safety Standards (MHCSS). However, work associated with the completion of hinged roofs and eaves in § 3285.801 and other work done on-site and not specifically identified in this part as close-up is considered construction and assembly and is subject to the requirements of the Manufactured Home Construction and Safety Standards (24 CFR part 3280) and the Manufactured Home Procedural and Enforcement Regulations (24 CFR part 3282). (1) States that choose to operate an installation program for manufactured homes in lieu of the federal program must implement installation standards that provide protection to its residents that equals or exceeds the protection provided by these Model Installation Standards. (2) In states that do not choose to… | |||||
| 24:24:5.1.2.1.5.1.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | A | Subpart A—General | § 3285.2 Manufacturer installation instructions. | HUD | (a) Instructions required. A manufacturer must provide with each new manufactured home, installation designs and instructions that have been approved by the Secretary or DAPIA. The approved installation instructions must include all topics covered in the Model Installation Standards for the installation of manufactured homes. These installation instructions and any variations thereto that are prepared to comply with paragraph (c) of this section must provide protection to residents of the manufactured homes that equals or exceeds the protection provided by these Model Installation Standards and must not take the manufactured home out of compliance with the MHCSS. These instructions must insure that each home will be supported and anchored in a manner that is capable of meeting or exceeding the design loads required by the MHCSS. (b) Professional engineer or registered architect certification. A professional engineer or registered architect must prepare and certify that the manufacturer's installation instructions meet or exceed the Model Installation Standards for foundation support and anchoring whenever: (1) The manufacturer's installation instructions do not conform in their entirety to the minimum requirements or tables or their conditions for foundation support and anchoring of this Standard; or (2) An alternative foundation system or anchoring system is employed, including designs for basements and perimeter support foundation systems, whether or not it is included in the installation instructions; or (3) Materials such as metal piers or alternatives to concrete footing materials are required by the installation instructions; or (4) Foundation support and anchoring systems are designed for use in areas subject to freezing or for use in areas subject to flood damage or high seismic risk; or (5) Foundations support and anchoring systems are designed to be used in special snow load conditions or in severe wind design areas; or (6) Site conditions do not allow the use of the manufacturer's installati… | |||||
| 24:24:5.1.2.1.5.1.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | A | Subpart A—General | § 3285.3 Alterations during initial installation. | HUD | Additions, modifications, or replacement or removal of any equipment that affects the installation of the home made by the manufacturer, retailer, or installer prior to completion of the installation by an installer must equal or exceed the protections and requirements of these Model Installation Standards, the MHCSS (24 CFR part 3280) and the Manufactured Home Procedural and Enforcement Regulations (24 CFR part 3282). An alteration, as defined in § 3282.7 of this chapter, must not affect the ability of the basic manufactured home to comply with the MHCSS, and the alteration must not impose additional loads to the manufactured home or its foundation, unless the alteration is included in the manufacturer's DAPIA-approved designs and installation instructions, or is designed by a registered professional engineer or architect consistent with the manufacturer's design and that conforms to the requirements of the MHCSS. | |||||
| 24:24:5.1.2.1.5.1.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | A | Subpart A—General | § 3285.4 Incorporation by reference (IBR). | HUD | (a) The materials listed in this section are incorporated by reference in the corresponding sections noted. These incorporations by reference were approved by the Director of the Federal Register, in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. The materials are available for purchase at the corresponding addresses noted below, and all are available for inspection at the Office of Manufactured Housing Programs, U.S. Department of Housing and Urban Development, 451 Seventh Street, SW., Room 9164, Washington, DC 20410; or the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call (202) 741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html. (b) The materials listed below are available for purchase from the Air Conditioning Contractors of America (ACCA), 2800 Shirlington Road, Suite 300, Arlington, Virginia 22206. (1) ACCA Manual J, Residential Load Calculation, 8th Edition, IBR approved for § 3285.503(a)(1)(i)(A). (2) [Reserved] (c) The materials listed below are available for purchase from APA—The Engineered Wood Association, 7011 South 19th Street, Tacoma, Washington 98411, telephone number (253) 565-6600, fax number (253) 565-7265. (1) PS1-95, Construction and Industrial Plywood (with typical APA trademarks), 1995 edition, IBR approved for § 3285.312(a)(2)(i). (2) [Reserved] (d) The materials listed below are available for purchase from American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), 1791 Tullie Circle, NE., Atlanta, Georgia 30329-2305. (1) ASHRAE Handbook of Fundamentals, 1997 Inch-Pound Edition, IBR approved for § 3285.503(a)(1)(i)(A). (2) [Reserved] (e) The materials listed below are available for purchase from American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, Pennsylvania 19428-2959. (1) ASTM C 90-02a, Standard Specification for Loadbearing Concrete Masonry Units, 2002, IBR approved for § 3285.312(a)(1)(i). (2) ASTM D 1… | |||||
| 24:24:5.1.2.1.5.1.1.5 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | A | Subpart A—General | § 3285.5 Definitions. | HUD | [72 FR 59362, Oct. 19, 2007, as amended at 79 FR 53614, Sept. 10, 2014; 80 FR 53731, Sept. 8, 2015; 86 FR 2526, Jan. 12, 2021; 89 FR 75758, Sept. 16, 2024] | The definitions contained in this section apply to the terms used in these Model Installation Standards. Where terms are not included, common usage of the terms applies. The definitions are as follows: Act. The National Manufactured Housing Construction and Safety Standards Act of 1974, 42 U.S.C. 5401-5426. Anchor assembly. Any device or other means designed to transfer home anchoring loads to the ground. Anchoring equipment. Ties, straps, cables, turnbuckles, chains, and other approved components, including tensioning devices that are used to secure a manufactured home to anchor assemblies. Anchoring system. A combination of anchoring equipment and anchor assemblies that will, when properly designed and installed, resist the uplift, overturning, and lateral forces on the manufactured home and on its support and foundation system. Approved. When used in connection with any material, appliance or construction, means complying with the requirements of the Department of Housing and Urban Development. Arid region. An area subject to 15 inches or less of annual rainfall. Attached accessory building or structure means any awning, cabana, deck, ramada, storage cabinet, carport, windbreak, garage, or porch for which the attachment of such is designed by the home manufacturer to be structurally supported by the manufactured home. Base flood. The flood having a one percent chance of being equaled or exceeded in any given year. Base flood elevation (BFE). The elevation of the base flood, including wave height, relative to the datum specified on a LAHJ's flood hazard map. Comfort cooling certificate. A certificate permanently affixed to an interior surface of the home specifying the factory design and preparations for air conditioning the manufactured home. Crossovers. Utility interconnections in multi-section homes that are located where the sections are joined. Crossover connections include heating and cooling ducts, electrical circuits, water pipes, drain plumbing, and gas lines. Design Approval Pri… | ||||
| 24:24:5.1.2.1.5.1.1.6 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | A | Subpart A—General | § 3285.6 Final leveling of manufactured home. | HUD | The manufactured home must be adequately leveled prior to completion of the installation, so that the home's performance will not be adversely affected. The home will be considered adequately leveled if there is no more than 1/4 inch difference between adjacent pier supports (frame or perimeter) and the exterior doors and windows of the home do not bind and can be properly operated. | |||||
| 24:24:5.1.2.1.5.10.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | J | Subpart J—Optional Information for Manufacturer's Installation Instructions | § 3285.901 General. | HUD | The planning and permitting processes, as well as utility connection, access, and other requirements, are outside of HUD's authority and may be governed by LAHJs. These Model Installation Standards do not attempt to comprehensively address such requirements. However, HUD recommends that the manufacturer's installation instructions include the information and advisories in this Subpart J, in order to protect the manufactured home, as constructed in accordance with the MHCSS. | |||||
| 24:24:5.1.2.1.5.10.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | J | Subpart J—Optional Information for Manufacturer's Installation Instructions | § 3285.902 Moving manufactured home to location. | HUD | It is recommended that the installation instructions indicate that the LAHJ be informed before moving the manufactured home to the site. It is also recommended that the installation instructions indicate that the manufactured home is not to be moved to the site until the site is prepared in accordance with subpart C of this part and when the utilities are available as required by the LAHJ. Examples of related areas that might be addressed in the installation instructions for meeting this recommendation include: (a) Access for the transporter. Before attempting to move a home, ensure that the transportation equipment and home can be routed to the installation site and that all special transportation permits required by the LAHJ have been obtained. (b) Drainage structures. Ditches and culverts used to drain surface runoff meet the requirements of the LAHJ and are considered in the overall site preparation. | |||||
| 24:24:5.1.2.1.5.10.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | J | Subpart J—Optional Information for Manufacturer's Installation Instructions | § 3285.903 Permits, alterations, and on-site structures. | HUD | [72 FR 59362, Oct. 19, 2007, as amended at 86 FR 2526, Jan. 12, 2021] | It is recommended that the installation instructions include the following information related to permits, alterations, and on-site structures: (a) Issuance of permits. All necessary LAHJ fees should be paid and permits should be obtained, which may include verification that LAHJ requirements regarding encroachments in streets, yards, and courts are obeyed and that permissible setback and fire separation distances from property lines and public roads are met. (b) Alterations. Prior to making any alteration to a home or its installation, contact the LAHJ to determine if plan approval and permits are required. (c) Installation of an add-on or attached accessory building or structure. Each attached accessory building or structure or add-on is designed to support all of its own live and dead loads, unless the attached accessory building or structure is otherwise included in the installation instructions or designed by a registered professional engineer or registered architect in accordance with this part. | ||||
| 24:24:5.1.2.1.5.10.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | J | Subpart J—Optional Information for Manufacturer's Installation Instructions | § 3285.904 Utility system connections. | HUD | (a) It is recommended that the manufacturer's installation instructions indicate the following procedures be used prior to making any utility system connection: (1) Where an LAHJ and utility services are available, that the LAHJ and all utility services each be consulted before connecting the manufactured home to any utilities, or (2) Where no LAHJ exists and utility services are available, that the utilities be consulted before connecting the manufactured home to any utility service; or (3) In rural areas where no LAHJ or utility services are available, that a professional be consulted prior to making any system connections. (b) Qualified personnel. Only qualified personnel familiar with local requirements are permitted to make utility site connections and conduct tests. (c) Drainage system. The main drain line must be connected to the site's sewer hookup, using an elastomeric coupler or by other methods acceptable to the LAHJ, as shown in Figure A to this section. (d) Fuel supply system. (1) Conversion of gas appliances. A service person acceptable to the LAHJ must convert the appliance from one type of gas to another, following instructions by the manufacturer of each appliance. (2) Orifices and regulators. Before making any connections to the site supply, the inlet orifices of all gas-burning appliances must be checked to ensure they are correctly set up for the type of gas to be supplied. (3) Connection procedures. Gas-burning appliance vents must be inspected to ensure that they are connected to the appliance and that roof jacks are properly installed and have not come loose during transit. (4) Gas appliance start-up procedures. The LAHJ should be consulted concerning the following gas appliance startup procedures: (i) One at a time, opening equipment shutoff valves, lighting pilot lights when provided, and adjusting burners and spark igniters for automatic ignition systems, in accordance with each appliance manufacturer instructions. (ii) Checking the operation of the furnace and w… | |||||
| 24:24:5.1.2.1.5.10.1.5 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | J | Subpart J—Optional Information for Manufacturer's Installation Instructions | § 3285.905 Heating oil systems. | HUD | It is recommended that the installation instructions include the following information related to heating oil systems, when applicable: (a) Homes equipped with oil burning furnaces should have their oil supply tank and piping installed and tested on-site, in accordance with NFPA 31, Standard for the Installation of Oil Burning Equipment, 2001 (incorporated by reference, see § 3285.4) or the LAHJ, whichever is more stringent. (b) The oil burning furnace manufacturer's instructions should be consulted for pipe size and installation procedures. (c) Oil storage tanks and pipe installations should meet all applicable local regulations. (d) Tank installation requirements. (1) The tank should be located where it is accessible to service and supply and where it is safe from fire and other hazards. (2) In flood hazard areas, the oil storage tank should be anchored and elevated to or above the design flood elevation, or anchored and designed to prevent flotation, collapse, or permanent lateral movement during the design flood. (3) Leak test procedure. Before the system is operated, it should be checked for leaks in the tank and supply piping, in accordance with NFPA 31, Standard for the Installation of Oil Burning Equipment, 2001 (incorporated by reference, see § 3285.4) or the requirements of the LAHJ, whichever is more stringent. | |||||
| 24:24:5.1.2.1.5.10.1.6 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | J | Subpart J—Optional Information for Manufacturer's Installation Instructions | § 3285.906 Telephone and cable TV. | HUD | It is recommended that the installation instructions explain that telephone and cable TV wiring should be installed in accordance with requirements of the LAHJ and the National Electrical Code, NFPA No. 70-2005 (incorporated by reference, see § 3285.4). | |||||
| 24:24:5.1.2.1.5.10.1.7 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | J | Subpart J—Optional Information for Manufacturer's Installation Instructions | § 3285.907 Manufacturer additions to installation instructions. | HUD | A manufacturer may include in its installation instructions items that are not required by this chapter as long as the items included by the manufacturer are consistent with the Model Installation Standards in this part and do not take the manufactured home out of compliance with the MHCSS. | |||||
| 24:24:5.1.2.1.5.2.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | B | Subpart B—Pre-Installation Considerations | § 3285.101 Fire separation. | HUD | Fire separation distances must be in accordance with the requirements of Chapter 6 of NFPA 501A, 2003 edition (incorporated by reference, see § 3285.4) or the requirements of the LAHJ. The installation instructions must clearly indicate this requirement in a separate section and must caution installers to take into account any local requirements on fire separation. | |||||
| 24:24:5.1.2.1.5.2.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | B | Subpart B—Pre-Installation Considerations | § 3285.102 Installation of manufactured homes in flood hazard areas. | HUD | (a) Definitions. Except to the extent otherwise defined in Subpart A, the terms used in this subpart are as defined in 44 CFR 59.1 of the National Flood Insurance Program (NFIP) regulations. (b) Applicability. The provisions of this section apply to the initial installation of new manufactured homes located wholly or partly within a flood hazard area. (c) Pre-installation considerations. Prior to the initial installation of a new manufactured home, the installer is responsible for determining whether the manufactured home site lies wholly or partly within a special flood hazard area as shown on the LAHJ's Flood Insurance Rate Map, Flood Boundary and Floodway Map, or Flood Hazard Boundary Map, or if no LAHJ, in accordance with NFIP regulations. If so located, and before an installation method is agreed upon, the map and supporting studies adopted by the LAHJ must be used to determine the flood hazard zone and base flood elevation at the site. (d) General elevation and foundation requirements —(1) Methods and practices. Manufactured homes located wholly or partly within special flood hazard areas must be installed on foundations engineered to incorporate methods and practices that minimize flood damage during the base flood, in accordance with the requirements of the LAHJ, 44 CFR 60.3(a) through (e), and other provisions of 44 CFR referenced by those paragraphs. (2) Outside appliances. (i) Appliances installed on the manufactured home site in flood hazard areas must be anchored and elevated to or above the same elevation as the lowest elevation of the lowest floor of the home. (ii) Appliance air inlets and exhausts in flood hazard areas must be located at or above the same elevation as the lowest elevation of the lowest floor of the home. (3) Related guidance. Refer to FEMA 85/September 1985, Manufactured Home Installation in Flood Hazard Areas, 1985 (incorporated by reference, see § 3285.4). | |||||
| 24:24:5.1.2.1.5.2.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | B | Subpart B—Pre-Installation Considerations | § 3285.103 Site suitability with design zone maps. | HUD | Prior to the initial installation of a new manufactured home and as part of making the certification of the installation required under part 3286, upon effect, the installer is to verify that the design and construction of the manufactured home, as indicated on the design zone maps provided with the home, are suitable for the site location where the home is to be installed. The design zone maps are those identified in part 3280 of this chapter. (a) Wind zone. Manufactured homes must not be installed in a wind zone that exceeds the design wind loads for which the home has been designed, as evidenced by the wind zone indicated on the home's data plate and as further defined by counties or local governments within affected states, as applicable, in § 3280.305(c)(2) of the Manufactured Home Construction and Safety Standards in this chapter. (b) Roof load zone. Manufactured homes must not be located in a roof load zone that exceeds the design roof load for which the home has been designed, as evidenced by the roof load zone indicated on the home's data plate and as further defined by counties or local governments within affected states, as applicable, in § 3280.305(c)(3) of the Manufactured Home Construction and Safety Standards in this chapter. Refer to § 3285.315 for Special Snow Load Conditions. (c) Thermal zone. Manufactured homes must not be installed in a thermal zone that exceeds the thermal zone for which the home has been designed, as evidenced by the thermal zone indicated on the heating/cooling certificate and insulation zone map and as further defined by counties or local governments within affected states, as applicable, in § 3280.504(b)(5) of the Manufactured Home Construction and Safety Standards in this chapter. The manufacturer may provide the heating/cooling information and insulation zone map on the home's data plate. | |||||
| 24:24:5.1.2.1.5.2.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | B | Subpart B—Pre-Installation Considerations | § 3285.104 Moving manufactured home to location. | HUD | Refer to § 3285.902 for considerations related to moving the manufactured home to the site of installation. | |||||
| 24:24:5.1.2.1.5.2.1.5 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | B | Subpart B—Pre-Installation Considerations | § 3285.105 Permits, other alterations, and on-site structures. | HUD | Refer to § 3285.903 for considerations related to permitting, other alterations, and on-site structures. | |||||
| 24:24:5.1.2.1.5.3.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | C | Subpart C—Site Preparation | § 3285.201 Soil conditions. | HUD | To help prevent settling or sagging, the foundation must be constructed on firm, undisturbed soil or fill compacted to at least 90 percent of its maximum relative density. All organic material such as grass, roots, twigs, and wood scraps must be removed in areas where footings are to be placed. After removal of organic material, the home site must be graded or otherwise prepared to ensure adequate drainage, in accordance with § 3285.203. | |||||
| 24:24:5.1.2.1.5.3.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | C | Subpart C—Site Preparation | § 3285.202 Soil classifications and bearing capacity. | HUD | The soil classification and bearing capacity of the soil must be determined before the foundation is constructed and anchored. The soil classification and bearing capacity must be determined by one or more of the following methods, unless the soil bearing capacity is established as permitted in paragraph (f) of this section: (a) Soil tests. Soil tests that are in accordance with generally accepted engineering practice; or (b) Soil records. Soil records of the applicable LAHJ; or (c) Soil classifications and bearing capacities. If the soil class or bearing capacity cannot be determined by test or soil records, but its type can be identified, the soil classification, allowable pressures, and torque values shown in Table to § 3285.202 may be used. (d) A pocket penetrometer; or (e) In lieu of determining the soil bearing capacity by use of the methods shown in the table, an allowable pressure of 1,500 psf may be used, unless the site-specific information requires the use of lower values based on soil classification and type. (f) If the soil appears to be composed of peat, organic clays, or uncompacted fill, or appears to have unusual conditions, a registered professional geologist, registered professional engineer, or registered architect must determine the soil classification and maximum allowable soil bearing capacity. Table to § 3285.202 Notes: 1 The values provided in this table have not been adjusted for overburden pressure, embedment depth, water table height, or settlement problems. 2 For soils classified as CH or MH, without either torque probe values or blow count test results, selected anchors must be rated for a 4B soil. 3 The torque test probe is a device for measuring the torque value of soils to assist in evaluating the holding capacity of the soil in which the ground anchor is placed. The shaft must be of suitable length for the full depth of the ground anchor. 4 The torque value is a measure of the load resistance provided by the soil when subject to the turning or twisting force… | |||||
| 24:24:5.1.2.1.5.3.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | C | Subpart C—Site Preparation | § 3285.203 Site Drainage. | HUD | (a) Purpose. Drainage must be provided to direct surface water away from the home to protect against erosion of foundation supports and to prevent water build-up under the home, as shown in Figure to § 3285.203. (b) The home site must be graded as shown in Figure to § 3285.203, or other methods, such as a drain tile and automatic sump pump system, must be provided to remove any water that may collect under the home. (c) All drainage must be diverted away from the home and must slope a minimum of one-half inch per foot away from the foundation for the first ten feet. Where property lines, walls, slopes, or other physical conditions prohibit this slope, the site must be provided with drains or swales or otherwise graded to drain water away from the structure, as shown in Figure to § 3285.203. (d) Sloped site considerations. The home, where sited, must be protected from surface runoff from the surrounding area. (e) Refer to § 3285.902 regarding the use of drainage structures to drain surface runoff. (f) Gutters and downspouts. Manufacturers must specify in their installation instructions whether the home is suitable for the installation of gutters and downspouts. If suitable, the installation instructions must indicate that when gutters and downspouts are installed, the runoff must be directed away from the home. | |||||
| 24:24:5.1.2.1.5.3.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | C | Subpart C—Site Preparation | § 3285.204 Ground moisture control. | HUD | (a) Vapor retarder. If the space under the home is to be enclosed with skirting or other materials, a vapor retarder must be installed to cover the ground under the home, unless the home is installed in an arid region with dry soil conditions. (b) Vapor retarder material. A minimum of six mil polyethylene sheeting or its equivalent must be used. (c) Proper installation. (1) The entire area under the home must be covered with the vapor retarder, as noted in § 3285.204(a), except for areas under open porches, decks, and recessed entries. Joints in the vapor retarder must be overlapped at least 12 inches. (2) The vapor retarder may be placed directly beneath footings, or otherwise installed around or over footings placed at grade, and around anchors or other obstructions. (3) Any voids or tears in the vapor retarder must be repaired. At least one repair method must be provided in the manufacturer's installation instructions. | |||||
| 24:24:5.1.2.1.5.4.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.301 General. | HUD | (a) Foundations for manufactured home installations must be designed and constructed in accordance with this subpart and must be based on site conditions, home design features, and the loads the home was designed to withstand, as shown on the home's data plate. (b) Foundation systems that are not pier and footing type configurations may be used when verified by engineering data and designed in accordance with § 3285.301(d), consistent with the design loads of the MHCSS. Pier and footing specifications that are different than those provided in this subpart, such as block size, metal piers, section width, loads, and spacing, may be used when verified by engineering data that comply with §§ 3285.301(c) and (d) and are capable of resisting all design loads of the MHCSS. (c) All foundation details, plans, and test data must be designed and certified by a registered professional engineer or registered architect, and must not take the home out of compliance with the MHCSS. (See 3285.2) (d) Alternative foundation systems or designs are permitted in accordance with either of the following: (1) Systems or designs must be manufactured and installed in accordance with their listings by a nationally recognized testing agency, based on a nationally recognized testing protocol; or (2) System designs must be prepared by a professional engineer or a registered architect or tested and certified by a professional engineer or registered architect in accordance with acceptable engineering practice and must be manufactured and installed so as not to take the home out of compliance with the Manufactured Home Construction and Safety Standards (part 3280 of this chapter). | |||||
| 24:24:5.1.2.1.5.4.1.10 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.310 Pier location and spacing. | HUD | (a) The location and spacing of piers depends upon the dimensions of the home, the live and dead loads, the type of construction (single-or multi-section), I-beam size, soil bearing capacity, footing size, and such other factors as the location of doors or other openings. (b) Mate-line and column pier supports must be in accordance with this subpart and consistent with Figures A through C to this section, unless the pier support and footing configuration is designed by a registered professional engineer or registered architect. (c) Piers supporting the frame must be no more than 24 inches from both ends and not more than 120 inches center to center under the main rails. (d) Pier support locations. Pier support locations and spacing must be presented to be consistent with Figures A and B to § 3285.312, as applicable, unless alternative designs are provided by a professional engineer or registered architect in accordance with acceptable engineering practice. 1. Bottom of footings must extend below frost line depth, unless designed for placement above the frost line. (See § 3285.312(b)). 2. Piers may be offset up to 6 in. in either direction along the supported members to allow for plumbing, electrical, mechanical, equipment, crawlspaces, or other devices. 3. Single-stack concrete block pier loads must not exceed 8,000 lbs. 4. Prefabricated piers must not exceed their approved or listed maximum vertical or horizontal design loads. 5. When a full-height mating wall does not support the ridge beam, this area is considered an unsupported span—Span B. 6. Piers are not required at openings in the mating wall that are less than 48 inches in width. Place piers on both sides of mating wall openings that are 48 inches or greater in width. For roof loads of 40 psf or greater, a professional engineer or registered architect must determine the maximum mating wall opening permitted without pier or other supports. 1. Bottom of footings must be below the frost line depth, unless designed for placement above the frost l… | |||||
| 24:24:5.1.2.1.5.4.1.11 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.311 Required perimeter supports. | HUD | (a) Perimeter pier or other supports must be located as follows: (1) On both sides of side wall exterior doors (such as entry, patio, and sliding glass doors) and any other side wall openings of 48 inches or greater in width, and under load-bearing porch posts, factory installed fireplaces, and fireplace stoves). (2) Other perimeter supports must be: (i) Located in accordance with Table 2 to § 3285.303; or (ii) Provided by other means such as additional outriggers or floor joists. When this alternative is used, the designs required by § 3285.301 must consider the additional loads in sizing the pier and footing supports under the main chassis beam. (b) For roof live loads of 40 psf or greater, a professional engineer or architect must determine the maximum sidewall opening permitted without perimeter pier or other supports. (c) The location and installation of any perimeter pier support must not take the home out of compliance with the Manufactured Home Construction and Safety Standards (part 3280 of this chapter). | |||||
| 24:24:5.1.2.1.5.4.1.12 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.312 Footings. | HUD | (a) Materials approved for footings must provide equal load-bearing capacity and resistance to decay, as required by this section. Footings must be placed on undisturbed soil or fill compacted to 90 percent of maximum relative density. A footing must support every pier. Footings are to be either: (1) Concrete. (i) Four inch nominal precast concrete pads meeting or exceeding ASTM C 90-02a, Standard Specification for Loadbearing Concrete Masonry Units (incorporated by reference, see § 3285.4), without reinforcement, with at least a 28-day compressive strength of 1,200 pounds per square inch (psi); or (ii) Six inch minimum poured-in-place concrete pads, slabs, or ribbons with at least a 28-day compressive strength of 3,000 pounds per square inch (psi). Site-specific soil conditions or design load requirements may also require the use of reinforcing steel in cast-in-place concrete footings. (2) Pressure-treated wood. (i) Pressure-treated wood footings must consist of a minimum of two layers of nominal 2-inch thick pressure-treated wood, a single layer of nominal 3/4 -inch thick, pressure-treated plywood with a maximum size of 16 inches by 16 inches, or at least two layers of 3/4 -inch thick, pressure-treated plywood for sizes greater than 16 inches by 16 inches. Plywood used for this purpose is to be rated exposure 1 or exterior sheathing, in accordance with PS1-95, Construction and Industrial Plywood (incorporated by reference, see § 3285.4). (ii) Pressure treated lumber is to be treated with a water-borne adhesive, in accordance with AWPA Standard U1-04 (incorporated by reference, see § 3285.4) for Use Category 4B ground contact applications. (iii) Cut ends of pressure treated lumber must be field-treated, in accordance with AWPA Standard M4-02 (incorporated by reference, see § 3285.4). (3) ABS footing pads. (i) ABS footing pads are permitted, provided they are installed in accordance with the pad manufacturer installation instructions and certified for use in the soil classification at the site. (… | |||||
| 24:24:5.1.2.1.5.4.1.13 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.313 Combination systems. | HUD | Support systems that combine both load-bearing capacity and uplift resistance must also be sized and designed for all applicable design loads. | |||||
| 24:24:5.1.2.1.5.4.1.14 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.314 [Reserved] | HUD | ||||||
| 24:24:5.1.2.1.5.4.1.15 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.315 Special snow load conditions. | HUD | (a) General. Foundations for homes designed for and located in areas with roof live loads greater than 40 psf must be designed by the manufacturer for the special snow load conditions, in accordance with acceptable engineering practice. Where site or other conditions prohibit the use of the manufacturer's instructions, a registered professional engineer or registered architect must design the foundation for the special snow load conditions. (b) Ramadas. Ramadas may be used in areas with roof live loads greater than 40 psf. Ramadas are to be self-supporting, except that any connection to the home must be for weatherproofing only. | |||||
| 24:24:5.1.2.1.5.4.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.302 Flood hazard areas. | HUD | In flood hazard areas, foundations, anchorings, and support systems must be capable of resisting loads associated with design flood and wind events or combined wind and flood events, and homes must be installed on foundation supports that are designed and anchored to prevent floatation, collapse, or lateral movement of the structure. Manufacturer's installation instructions must indicate whether: (a) The foundation specifications have been designed for flood-resistant considerations, and, if so, the conditions of applicability for velocities, depths, or wave action; or (b) The foundation specifications are not designed to address flood loads. | |||||
| 24:24:5.1.2.1.5.4.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.303 Piers. | HUD | (a) General. The piers used must be capable of transmitting the vertical live and dead loads to the footings or foundation. (b) Acceptable piers—materials specification. (1) Piers are permitted to be concrete blocks; pressure-treated wood with a water borne preservative, in accordance with AWPA Standard U1-04 (incorporated by reference, see § 3285.4) for Use Category 4B ground contact applications; or adjustable metal or concrete piers. (2) Manufactured piers must be listed or labeled for the required vertical load capacity, and, where required by design, for the appropriate horizontal load capacity. (c) Design requirements. (1) Load-bearing capacity. The load bearing capacity for each pier must be designed to include consideration for the dimensions of the home, the design dead and live loads, the spacing of the piers, and the way the piers are used to support the home. (2) Center beam/mating wall support must be required for multi-section homes and designs must be consistent with Tables 2 and 3 to § 3285.303 and Figures A, B, and C to § 3285.310. (d) Pier loads. (1) Design support configurations for the pier loads, pier spacing, and roof live loads must be in accordance with Tables 1, 2, and 3 to § 3285.303 and the MHCSS. Other pier designs are permitted in accordance with the provisions of this subpart. (2) Manufactured piers must be rated at least to the loads required to safely support the dead and live loads, as required by § 3285.301, and the installation instructions for those piers must be consistent with Tables 1, 2, and 3 to this section. Table 1 to § 3285.303—Frame Blocking Only/Perimeter Support Not Required Except at Openings 1. See Table to § 3285.312 for cast-in-place footing design by using the noted loads. 2. Table 1 is based on the following design assumptions: maximum 16 ft. nominal section width (15 ft. actual width), 12” eave, 10” I-beam size, 300 lbs. pier dead load, 10 psf roof dead load, 6 psf floor dead load, 35 plf wall dead load, and 10 plf chassis dead load. 3. Int… | |||||
| 24:24:5.1.2.1.5.4.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.304 Pier configuration. | HUD | (a) Concrete blocks. Installation instructions for concrete block piers must be developed in accordance with the following provisions and must be consistent with Figures A and B to § 3285.306. (1) Load-bearing (not decorative) concrete blocks must have nominal dimensions of at least 8 inches × 8 inches × 16 inches; (2) The concrete blocks must be stacked with their hollow cells aligned vertically; and (3) When piers are constructed of blocks stacked side-by-side, each layer must be at right angles to the preceding one, as shown in Figure B to § 3285.306. (b) Caps. (1) Structural loads must be evenly distributed across capped-hollow block piers, as shown in Figures A and B to § 3285.306. (2) Caps must be solid concrete or masonry at least 4 inches in nominal thickness, or hardboard lumber at least 2 inches nominal in thickness; or be corrosion-protected minimum one-half inch thick steel; or be of other listed materials. (3) All caps must be of the same length and width as the piers on which they rest. (4) When split caps are used on double-stacked blocks, the caps must be installed with the long dimension across the joint in the blocks below. (c) Gaps. Any gaps that occur during installation between the bottom of the main chassis beam and foundation support system must be filled by: (1) Nominal 4 inch × 6 inch × 1 inch shims to level the home and fill any gaps between the base of the main chassis beam and the top of the pier cap; (2) Shims must be used in pairs, as shown in Figures A and B to § 3285.306, and must be driven in tightly so that they do not occupy more than one inch of vertical height; and (3) Hardwood plates no thicker than 2 inches nominal in thickness or 2 inch or 4 inch nominal concrete block must be used to fill in any remaining vertical gaps. (d) Manufactured pier heights. Manufactured pier heights must be selected so that the adjustable risers do not extend more than 2 inches when finally positioned. | |||||
| 24:24:5.1.2.1.5.4.1.5 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.305 Clearance under homes. | HUD | A minimum clearance of 12 inches must be maintained between the lowest member of the main frame (I-beam or channel beam) and the grade under all areas of the home. | |||||
| 24:24:5.1.2.1.5.4.1.6 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.306 Design procedures for concrete block piers. | HUD | (a) Frame piers less than 36 inches high. (1) Frame piers less than 36 inches high are permitted to be constructed of single, open, or closed-cell concrete blocks, 8 inches “ 8 inches “ 16 inches, when the design capacity of the block is not exceeded. (2) The frame piers must be installed so that the long sides are at right angles to the supported I-beam, as shown in Figure A to this section. (3) The concrete blocks must be stacked with their hollow cells aligned vertically and must be positioned at right angles to the footings. (4) Horizontal offsets from the top to the bottom of the pier must not exceed one-half inch. (5) Mortar is not required, unless specified in the installation instructions or required by a registered professional engineer or registered architect. (b) Frame piers 36 inches to 67 inches high and corner piers. (1) All frame piers between 36 inches and 67 inches high and all corner piers over three blocks high must be constructed out of double, interlocked concrete blocks, as shown in Figure B to this section, when the design capacity of the block is not exceeded. Mortar is not required for concrete block piers, unless otherwise specified in the installation instructions or required by a professional engineer or registered architect. (2) Horizontal offsets from the top to the bottom of the pier must not exceed one inch. (c) All piers over 67 inches high. Piers over 67 inches high must be designed by a registered professional engineer or registered architect, in accordance with acceptable engineering practice. Mortar is not required for concrete block piers, unless otherwise specified in the manufacturer installation instructions or by the design. | |||||
| 24:24:5.1.2.1.5.4.1.7 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.307 Perimeter support piers. | HUD | (a) Piers required at mate-line supports, perimeter piers, and piers at exterior wall openings are permitted to be constructed of single open-cell or closed-cell concrete blocks, with nominal dimensions of 8 inches × 8 inches × 16 inches, to a maximum height of 54 inches, as shown in Figure A to this section, when the design capacity of the block is not exceeded. (b) Piers used for perimeter support must be installed with the long dimension parallel to the perimeter rail. | |||||
| 24:24:5.1.2.1.5.4.1.8 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.308 Manufactured piers. | HUD | (a) Manufactured piers must be listed and labeled and installed to the pier manufacturer's installation instructions. See § 3285.303(d)(2) for additional requirements. (b) Metal or other manufactured piers must be provided with protection against weather deterioration and corrosion at least equivalent to that provided by a coating of zinc on steel of .30 oz./ft. 2 of surface coated. | |||||
| 24:24:5.1.2.1.5.4.1.9 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | D | Subpart D—Foundations | § 3285.309 [Reserved] | HUD | ||||||
| 24:24:5.1.2.1.5.5.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | E | Subpart E—Anchorage Against Wind | § 3285.401 Anchoring instructions. | HUD | (a) After blocking and leveling, the manufactured home must be secured against the wind by use of anchor assembly type installations or by connecting the home to an alternative foundation system. See § 3285.301. (b) For anchor assembly type installations, the installation instructions must require the home to be secured against the wind, as described in this section. The installation instructions and design for anchor type assemblies must be prepared by a registered professional engineer or registered architect, in accordance with acceptable engineering practice, the design loads of the MHCSS, and § 3285.301(d). (c) All anchoring and foundation systems must be capable of meeting the loads that the home was designed to withstand required by part 3280, subpart D of this chapter, as shown on the home's data plate. Exception: Manufactured homes that are installed in less restrictive roof load zone and wind zone areas may have foundation or anchorage systems that are capable of meeting the lower design load provisions of the Standards, if the design for the lower requirements is either provided in the installation instructions or the foundation and anchorage system is designed by a professional engineer or registered architect. (d) The installation instructions are to include at least the following information and details for anchor assembly-type installations: (1) The maximum spacing for installing diagonal ties and any required vertical ties or straps to ground anchors; (2) The minimum and maximum angles or dimensions for installing diagonal ties or straps to ground anchors and the main chassis members of the manufactured home; (3) Requirements for connecting the diagonal ties to the main chassis members of the manufactured home. If the diagonal ties are attached to the bottom flange of the main chassis beam, the frame must be designed to prevent rotation of the beam; (4) Requirements for longitudinal and mating wall tie-downs and anchorage; (5) The method of strap attachment to the main chassis member and g… | |||||
| 24:24:5.1.2.1.5.5.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | E | Subpart E—Anchorage Against Wind | § 3285.402 Ground anchor installations. | HUD | [72 FR 59362, Oct. 19, 2007, as amended at 79 FR 53614, Sept. 10, 2014] | (a) Ground anchor certification and testing. (1) Each ground anchor assembly must be manufactured and provided with installation instructions, and must be labeled or otherwise identified and subject to an on-going quality assurance surveillance program in accordance with its listing or certification (see 24 CFR 3285.5) by a nationally recognized testing laboratory. A registered professional engineer or architect must certify that each ground anchor assembly is capable of resisting all loads in paragraph (c) of this section based on the test methods in paragraph (b) of this section for use in soil(s) classified in accordance with § 3285.202. (2) Each ground anchor assembly that has been listed prior to November 10, 2014 is not subject to paragraph (b) of this section, provided it has been previously tested in accordance with this paragraph. A professional engineer or registered architect must have certified the testing. The ground anchor must be listed by a nationally recognized testing agency and the listing or certification includes or has met all of the following requirements: (i) A minimum of three tests meeting all of the requirements of this section were conducted for each ground anchor assembly design; (ii) Each of the ground anchor assembly designs tested must have met or exceeded a working load of 3,150 pounds and sustained an ultimate load of 4,725 pounds in the weakest soil classification for which the anchors were tested and certified; (iii) The soil in which the anchor was certified has been classified by one of the methods indicated in § 3285.202 of these Standards and the anchor is not listed for use in a weaker/higher soil classification than tested and identified in the Table to § 3285.202; (iv) A test report was provided for each ground anchor assembly design that identifies the soil classification in which the ground anchor was tested and listed and includes complete specifications and dimensions for the ground anchor assembly; (v) For each of the ground anchor assemblies tested, the max… | ||||
| 24:24:5.1.2.1.5.5.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | E | Subpart E—Anchorage Against Wind | § 3285.403 Sidewall, over-the-roof, mate-line, and shear wall straps. | HUD | If sidewall, over-the-roof, mate-line, or shear wall straps are installed on the home, they must be connected to an anchoring assembly. | |||||
| 24:24:5.1.2.1.5.5.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | E | Subpart E—Anchorage Against Wind | § 3285.404 Severe climatic conditions. | HUD | In frost-susceptible soil locations, ground anchor augers must be installed below the frost line, unless the foundation system is frost-protected to prevent the effects of frost heave, in accordance with acceptable engineering practice and § 3280.306 of this chapter and § 3285.312. | |||||
| 24:24:5.1.2.1.5.5.1.5 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | E | Subpart E—Anchorage Against Wind | § 3285.405 Severe wind zones. | HUD | When any part of a home is installed within 1,500 feet of a coastline in Wind Zones II or III, the manufactured home must be designed for the increased requirements, as specified on the home's data plate (refer to § 3280.5(f) of this chapter) in accordance with acceptable engineering practice. Where site or other conditions prohibit the use of the manufacturer's instructions, a registered professional engineer or registered architect, in accordance with acceptable engineering practice, must design anchorage for the special wind conditions. | |||||
| 24:24:5.1.2.1.5.5.1.6 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | E | Subpart E—Anchorage Against Wind | § 3285.406 Flood hazard areas. | HUD | Refer to § 3285.302 for anchoring requirements in flood hazard areas. | |||||
| 24:24:5.1.2.1.5.6.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | F | Subpart F—Optional Features | § 3285.501 Home installation manual supplements. | HUD | Supplemental instructions for optional equipment or features must be approved by the DAPIA as not taking the home out of conformance with the requirements of this part, or part 3280 of this chapter, and included with the manufacturer installation instructions. | |||||
| 24:24:5.1.2.1.5.6.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | F | Subpart F—Optional Features | § 3285.502 Expanding rooms. | HUD | The support and anchoring systems for expanding rooms must be installed in accordance with designs provided by the home manufacturer or prepared by a registered professional engineer or registered architect, in accordance with acceptable engineering practice. | |||||
| 24:24:5.1.2.1.5.6.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | F | Subpart F—Optional Features | § 3285.503 Optional appliances. | HUD | [72 FR 59362, Oct. 19, 2007, as amended at 89 FR 75758, Sept. 16, 2024] | (a) Comfort cooling systems. When not provided and installed by the home manufacturer, any comfort cooling systems that are installed must be installed according to the appliance manufacturer's installation instructions. (1) Air conditioners. Air conditioning equipment must be listed or certified by a nationally recognized testing agency for the application for which the unit is intended and installed in accordance with the terms of its listing or certification (see § 3280.714 of this chapter). (i) Energy efficiency. (A) Site-installed central air conditioning equipment must be sized to meet the home's heat gain requirement, in accordance with Chapter 28 of the 1997 ASHRAE Handbook of Fundamentals (incorporated by reference, see § 3285.4) or ACCA Manual J, Residential Cooling Load, 8th Edition (incorporated by reference, see § 3285.4). Information necessary to calculate the home's heat gain can be found on the home's comfort cooling certificate. (B) The BTU/hr. rated capacity of the site-installed air conditioning equipment must not exceed the air distribution system's rated BTU/hr. capacity as shown on the home's compliance certificate. (ii) Circuit rating. If a manufactured home is factory-provided with an exterior outlet to energize heating and/or air conditioning equipment, the branch circuit rating on the tag adjacent to this outlet must be equal to or greater than the minimum circuit amperage identified on the equipment rating plate. (iii) A-coil units. (A) A-coil air conditioning units must be compatible and listed for use with the furnace in the home and installed in accordance with the appliance manufacturer's instructions. (B) The air conditioner manufacturer instructions must be followed. (C) All condensation must be directed beyond the perimeter of the home by means specified by the equipment manufacturer. (2) Heat pumps. Heat pumps must be listed or certified by a nationally recognized testing agency for the application for which the unit is intended and installed in accordance wi… | ||||
| 24:24:5.1.2.1.5.6.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | F | Subpart F—Optional Features | § 3285.504 Skirting. | HUD | (a) Skirting, if used, must be of weather-resistant materials or provided with protection against weather deterioration at least equivalent to that provided by a coating of zinc on steel of not less than 0.30 oz./ft. 2 of surface coated. (b) Skirting must not be attached in a manner that can cause water to be trapped between the siding and trim or forced up into the wall cavities trim to which it is attached. (c) All wood skirting within 6 inches of the ground must be pressure-treated in accordance with AWPA Standard U1 (incorporated by reference, see § 3285.4) for Use Category 4A, Ground Anchor Contact Applications, or be naturally resistant to decay and termite infestations. (d) Skirting must not be attached in a manner that impedes the contraction and expansion characteristics of the home's exterior covering. | |||||
| 24:24:5.1.2.1.5.6.1.5 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | F | Subpart F—Optional Features | § 3285.505 Crawlspace ventilation. | HUD | (a) A crawlspace with skirting must be provided with ventilation openings. The minimum net area of ventilation openings must not be less than one square foot (ft. 2 ) for every 150 square feet (ft. 2 ) of the home's floor area. The total area of ventilation openings may be reduced to one square foot (ft. 2 ) for every 1,500 square feet (ft. 2 ) of the home's floor area, where a uniform 6-mil polyethylene sheet material or other acceptable vapor retarder is installed, according to § 3285.204, on the ground surface beneath the entire floor area of the home. (b) Ventilation openings must be placed as high as practicable above the ground. (c) Ventilation openings must be located on at least two opposite sides to provide cross-ventilation. (d) Ventilation openings must be covered for their full height and width with a perforated corrosion and weather-resistant covering that is designed to prevent the entry of rodents. In areas subject to freezing, the coverings for the ventilation openings must also be of the adjustable type, permitting them to be in the open or closed position, depending on the climatic conditions. (e) Access opening(s) not less than 18 inches in width and 24 inches in height and not less than three square feet (ft. 2 ) in area must be provided and must be located so that any utility connections located under the home are accessible. (f) Dryer vents and combustion air inlets must pass through the skirting to the outside. Any surface water runoff from the furnace, air conditioning, or water heater drains must be directed away from under the home or collected by other methods identified in § 3285.203. | |||||
| 24:24:5.1.2.1.5.6.1.6 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | F | Subpart F—Optional Features | § 3285.506 Testing and certification for fire sprinkler systems. | HUD | [89 FR 75758, Sept. 16, 2024] | The installer shall ensure that a fire protection technician certifies and tests residential fire sprinkler systems on site in accordance with the home manufacturer's instructions and as outlined in § 3280.214 of this chapter. The fire protection technician conducting the required testing should complete and Fire Sprinkler System Certificate so that a required listed minimum water supply is reported as available for the system. The installer will provide the testing requirements specified in § 3280.612(a) of this chapter and maintain a copy of the test report collected from the fire protection technician. | ||||
| 24:24:5.1.2.1.5.7.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | G | Subpart G—Ductwork and Plumbing and Fuel Supply Systems | § 3285.601 Field assembly. | HUD | Home manufacturers must provide specific installation instructions for the proper field assembly of manufacturer-supplied and shipped loose ducts, plumbing, and fuel supply system parts that are necessary to join all sections of the home and are designed to be located underneath the home. The installation instructions must be designed in accordance with applicable requirements of part 3280, subparts G and H, of this chapter, as specified in this subpart. | |||||
| 24:24:5.1.2.1.5.7.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | G | Subpart G—Ductwork and Plumbing and Fuel Supply Systems | § 3285.602 Utility connections. | HUD | Refer to § 3285.904 for considerations for utility system connections. | |||||
| 24:24:5.1.2.1.5.7.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | G | Subpart G—Ductwork and Plumbing and Fuel Supply Systems | § 3285.603 Water supply. | HUD | [72 FR 59362, Oct. 19, 2007, as amended at 89 FR 75758, Sept. 16, 2024] | (a) Crossover. Multi-section homes with plumbing in both sections require water-line crossover connections to join all sections of the home. The crossover design requirements are located in, and must be designed in accordance with, § 3280.609 of this chapter. (b) Maximum supply pressure and reduction. When the local water supply pressure exceeds 80 psi to the manufactured home, a pressure-reducing valve must be installed. (c) Mandatory shutoff valve. (1) An identified and accessible shutoff valve must be installed between the water supply and the inlet. (2) The water riser for the shutoff valve connection must be located underneath or adjacent to the home. (3) The shutoff valve must be a full-flow gate or ball valve, or equivalent valve. (d) Freezing protection. Water line crossovers completed during installation must be protected from freezing. The freeze protection design requirements are located in, and must be designed in accordance with, § 3280.603 of this chapter. (1) If subject to freezing temperatures, the water connection must be wrapped with insulation or otherwise protected to prevent freezing. (2) In areas subject to freezing or subfreezing temperatures, exposed sections of water supply piping, shutoff valves, pressure reducers, and pipes in water heater compartments must be insulated or otherwise protected from freezing. (3) Only heat tape or pipe heating cable listed and certified for its intended purpose is permitted for use, and it must be installed in accordance with tape or cable manufacturer installation instructions. (e) Testing procedures. (1) The water system must be inspected and tested for leaks after completion at the site. The installation instructions must provide testing requirements that are in accordance with the piping manufacturer's instructions. (2) The water heater must be disconnected when using an air-only test. | ||||
| 24:24:5.1.2.1.5.7.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | G | Subpart G—Ductwork and Plumbing and Fuel Supply Systems | § 3285.604 Drainage system. | HUD | (a) Crossovers. Multi-section homes with plumbing in more than one section require drainage system crossover connections to join all sections of the home. The crossover design requirements are located in, and must be designed in accordance with, § 3280.610 of this chapter. (b) Assembly and support. If portions of the drainage system were shipped loose because they were necessary to join all sections of the home and designed to be located underneath the home, they must be installed and supported in accordance with § 3280.608 of this chapter. (c) Proper slopes. Drains must be completed in accordance with § 3280.610 of this chapter. (1) Drain lines must not slope less than one-quarter inch per foot, unless otherwise noted on the schematic diagram, as shown in Figure to § 3285.604. (2) A slope of one-eight inch per foot may be permitted when a clean-out is installed at the upper end of the run. (d) Testing procedures. The drainage system must be inspected and tested for leaks after completion at the site. The installation instructions must provide testing requirements that are consistent with § 3280.612 of this chapter. | |||||
| 24:24:5.1.2.1.5.7.1.5 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | G | Subpart G—Ductwork and Plumbing and Fuel Supply Systems | § 3285.605 Fuel supply system. | HUD | (a) Proper supply pressure. The gas piping system in the home is designed for a pressure that is at least 7 inches of water column [4oz./in. 2 or 0.25 psi] and not more than 14 inches of water column [8 oz./in. 2 or 0.5 psi]. If gas from any supply source exceeds, or could exceed this pressure, a regulator must be installed if required by the LAHJ. (b) Crossovers. (1) Multi-section homes with fuel supply piping in both sections require crossover connections to join all sections of the home. The crossover design requirements are located in, and must be designed in accordance with, § 3280.705 of this chapter. (2) Tools must not be required to connect or remove the flexible connector quick-disconnect. (c) Testing procedures. The gas system must be inspected and tested for leaks after completion at the site. The installation instructions must provide testing requirements that are consistent with § 3280.705 of this chapter. | |||||
| 24:24:5.1.2.1.5.7.1.6 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | G | Subpart G—Ductwork and Plumbing and Fuel Supply Systems | § 3285.606 Ductwork connections. | HUD | (a) Multi-section homes with ductwork in more than one section require crossover connections to complete the duct system of the home. All ductwork connections, including duct collars, must be sealed to prevent air leakage. Galvanized metal straps or tape and mastics listed to UL 181A (incorporated by reference, see § 3285.4), for closure systems with rigid air ducts and connectors, or UL 181B (incorporated by reference, see § 3285.4), for closure systems with flexible air ducts and connectors, must be used around the duct collar and secured tightly to make all connections. (b) If metal straps are used, they must be secured with galvanized sheet metal screws. (c) Metal ducts must be fastened to the collar with a minimum of three galvanized sheet metal screws equally spaced around the collar. (d) Air conditioning or heating ducts must be installed in accordance with applicable requirements of the duct manufacturer installation instructions. (e) The duct must be suspended or supported above the ground by straps or other means that are spaced at a maximum distance not to exceed 4′-0″ or as otherwise permitted by the installation instructions. When straps are used to support a flexible type duct, the straps must be at least 1/2 ″ wider than the spacing of the metal spirals encasing the duct. The ducts must be installed such that the straps cannot slip between any two spirals and arranged under the floor to prevent compression or kinking in any location, as shown in Figures A and B to this section. In-floor crossover ducts are permitted, in accordance with § 3285.606(g). (f) Crossover ducts outside the thermal envelope must be insulated with materials that conform to designs consistent with part 3280, subpart F of this chapter. (g) In-floor or ceiling crossover duct connections must be installed and sealed to prevent air leakage. 1. This system is typically used when a crossover duct has not been built into the floor and the furnace is outside the I-Beam. With this type of installation, it is necessary for two… | |||||
| 24:24:5.1.2.1.5.8.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | H | Subpart H—Electrical Systems and Equipment | § 3285.701 Electrical crossovers. | HUD | Multi-section homes with electrical wiring in more than one section require crossover connections to join all sections of the home. The crossover must be designed in accordance with part 3280, subpart I of this chapter, and completed in accordance with the directions provided in the installation instructions. | |||||
| 24:24:5.1.2.1.5.8.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | H | Subpart H—Electrical Systems and Equipment | § 3285.702 Miscellaneous lights and fixtures. | HUD | [72 FR 59362, Oct. 19, 2007; 72 FR 62308, Nov. 2, 2007] | (a) When the home is installed, exterior lighting fixtures, ceiling-suspended (paddle) fans, and chain-hung lighting fixtures are permitted to be installed in accordance with their listings and part 3280, subpart I of this chapter. (b) Grounding. (1) All the exterior lighting fixtures and ceiling fans installed per § 3285.702(a) must be grounded by a fixture-grounding device or by a fixture-grounding wire. (2) For chain-hung lighting fixtures, as shown in Figure A to this section, both a fixture-grounding device and a fixture-grounding wire must be used. The identified conductor must be the neutral conductor. (c) Where lighting fixtures are mounted on combustible surfaces such as hardboard, a limited combustible or noncombustible ring, as shown in Figures A and B to this section, must be installed to completely cover the combustible surface exposed between the fixture canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and wire-to-wire connections must be made using listed wire connectors. (2) Wires must be connected black-to-black, white-to-white, and equipment ground-to-equipment ground. (3) The wires must be pushed into the box, and the lighting fixture must be secured to the junction box. (4) The lighting fixture must be caulked around its base to ensure a watertight seal to the sidewall. (5) The light bulb must be installed and the globe must be attached. (e) Ceiling fans. (1) Ceiling-suspended (paddle) fans must be connected to junction box listed and marked for ceiling fan application, in accordance with Article 314.27(b) of the National Electrical Code, NFPA No. 70-2005 (incorporated by reference, see § 3285.4); and (2) The ceiling fan must be installed with the trailing edges of the blades at least 6 feet 4 inches above the finished floor; and (3) The wiring must be connected in accordance with the product manufacturer installation instructions. (f) Testing. (1) After completion of all electrical wiring and connections, including crossove… | ||||
| 24:24:5.1.2.1.5.8.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | H | Subpart H—Electrical Systems and Equipment | § 3285.703 Smoke alarms. | HUD | Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke alarm manufacturer instructions and must be consistent with § 3280.208 of this chapter. | |||||
| 24:24:5.1.2.1.5.8.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | H | Subpart H—Electrical Systems and Equipment | § 3285.704 Telephone and cable TV. | HUD | Refer to § 3285.906 for considerations pertinent to installation of telephone and cable TV. | |||||
| 24:24:5.1.2.1.5.9.1.1 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | I | Subpart I—Exterior and Interior Close-Up | § 3285.801 Exterior close-up. | HUD | [72 FR 59362, Oct. 19, 2007, as amended at 80 FR 53731, Sept. 8, 2015; 89 FR 75758, Sept. 16, 2024] | (a) Exterior siding and roofing necessary to join all sections of the home must be installed according to the product manufacturer installation instructions and must be fastened in accordance with designs and manufacturer instructions, consistent with §§ 3280.305 and 3280.307 of this chapter. Exterior close-up strips/trim must be fastened securely and sealed with exterior sealant (see figure A to this section). (b) Joints and seams. All joints and seams in exterior wall coverings that were disturbed during location of the home must be made weatherproof. (c) Prior to installing the siding, the polyethylene sheeting covering exterior walls for transit must be completely removed. (d) Prior to completing the exterior close-up, any holes in the roofing must be made weatherproof and sealed with a sealant or other material that is suitable for use with the roofing in which the hole is made. (e) Mate-line gasket. The home manufacturer must provide materials and designs for mate-line gaskets or other methods designed to resist the entry of air, water, water vapor, insects, and rodents at all mate-line locations exposed to the exterior (see Figure B to this section). (f) Hinged roofs and eaves. Hinged roofs and eaves must be completed during installation in compliance with all requirements of the Manufactured Home Construction and Safety Standards (24 CFR part 3280) and the Manufactured Home Procedural and Enforcement Regulations (24 CFR part 3282). Unless exempted by the following provisions, hinged roofs are also subject to a final inspection for compliance with the Manufactured Home Construction and Safety Standards (24 CFR part 3280) by the IPIA or a qualified independent inspector acceptable to the IPIA. Homes with hinged roofs that are exempted from IPIA inspection are instead to be completed and inspected in accordance with the Manufactured Home Installation Program (24 CFR part 3286). This includes homes: (1) That are designed to be located in Wind Zone I; (2) In which the roof pitch of the hinged roof… | ||||
| 24:24:5.1.2.1.5.9.1.2 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | I | Subpart I—Exterior and Interior Close-Up | § 3285.802 Structural interconnection of multi-section homes. | HUD | (a) For multi-section homes, structural interconnections along the interior and exterior at the mate-line are necessary to join all sections of the home. (b) Structural interconnection must be designed in accordance with the requirements located in § 3280.305 of this chapter to ensure a completely integrated structure. (c) Upon completion of the exterior close-up, no gaps are permitted between the structural elements being interconnected along the mate-line of multi-section homes. However, prior to completion of the exterior close-up, gaps that do not exceed one inch are permitted between structural elements provided: (1) The gaps are closed before completion of close-up; (2) The home sections are in contact with each other; and (3) The mating gasket is providing a proper seal. All such gaps must be shimmed with dimensional lumber, and fastener lengths used to make connections between the structural elements must be increased to provide adequate penetration into the receiving member. | |||||
| 24:24:5.1.2.1.5.9.1.3 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | I | Subpart I—Exterior and Interior Close-Up | § 3285.803 Interior close-up. | HUD | (a) All shipping blocking, strapping, or bracing must be removed from appliances, windows, and doors. (b) Interior close up items necessary to join all sections of the home or items subject to transportation damage may be packaged or shipped with the home for site installation. (c) Shipped-loose wall paneling necessary for the joining of all sections of the home must be installed by using polyvinyl acetate (PVA) adhesive on all framing members and fastened with minimum 1 1/2 inch long staples or nails at 6 inches on center panel edges and 12 inches on center in the field, unless alternative fastening methods are permitted in the installation instructions (see Figure A to § 3285.803). Specific designs must be approved by a DAPIA and included in the home manufacturer installation instructions. | |||||
| 24:24:5.1.2.1.5.9.1.4 | 24 | Housing and Urban Development | XX | 3285 | PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS | I | Subpart I—Exterior and Interior Close-Up | § 3285.804 Bottom board repair. | HUD | (a) The bottom board covering must be inspected for any loosening or areas that might have been damaged or torn during installation or transportation. Any missing insulation is to be replaced prior to closure and repair of the bottom board. (b) Any splits or tears in the bottom board must be resealed with tape or patches in accordance with methods provided in the manufacturers installation instructions. (c) Plumbing P-traps must be checked to be sure they are well-insulated and covered. (d) All edges of repaired areas must be taped or otherwise sealed. |
Advanced export
JSON shape: default, array, newline-delimited, object
CREATE TABLE cfr_sections (
section_id TEXT PRIMARY KEY,
title_number INTEGER,
title_name TEXT,
chapter TEXT,
subchapter TEXT,
part_number TEXT,
part_name TEXT,
subpart TEXT,
subpart_name TEXT,
section_number TEXT,
section_heading TEXT,
agency TEXT,
authority TEXT,
source_citation TEXT,
amendment_citations TEXT,
full_text TEXT
);
CREATE INDEX idx_cfr_title ON cfr_sections(title_number);
CREATE INDEX idx_cfr_part ON cfr_sections(part_number);
CREATE INDEX idx_cfr_agency ON cfr_sections(agency);