| section_id ▼ | title_number | title_name | chapter | subchapter | part_number | part_name | subpart | subpart_name | section_number | section_heading | agency | authority | source_citation | amendment_citations | full_text |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 21:21:8.0.1.1.19.1.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | A | Subpart A—General Provisions | § 864.1 Scope. | FDA | [52 FR 17732, May 11, 1987, as amended at 69 FR 12273, Mar. 16, 2004; 78 FR 18233, Mar. 26, 2013; 79 FR 50552, Aug. 25, 2014] | (a) This part sets forth the classification of hematology and pathology devices intended for human use that are in commercial distribution. (b) The identification of a device in a regulation in this part is not a precise description of every device that is, or will be, subject to the regulation. A manufacturer who submits a premarket notification submission for a device under part 807 may not show merely that the device is accurately described by the section title and identification provisions of a regulation in this part, but shall state why the device is substantially equivalent to other devices, as required by § 807.87. (c) References in this part to regulatory sections of the Code of Federal Regulations are to chapter I of title 21, unless otherwise noted. (d) Guidance documents referenced in this part are available on the Internet at http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/default.htm. | |||
| 21:21:8.0.1.1.19.1.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | A | Subpart A—General Provisions | § 864.3 Effective dates of requirement for premarket approval. | FDA | [52 FR 17732, May 11, 1987] | A device included in this part that is classified into class III (premarket approval) shall not be commercially distributed after the date shown in the regulation classifying the device unless the manufacturer has an approval under section 515 of the act (unless an exemption has been granted under section 520(g)(2) of the act). An approval under section 515 of the act consists of FDA's issuance of an order approving an application for premarket approval (PMA) for the device or declaring completed a product development protocol (PDP) for the device. (a) Before FDA requires that a device commercially distributed before the enactment date of the amendments, or a device that has been found substantially equivalent to such a device, has an approval under section 515 of the act FDA must promulgate a regulation under section 515(b) of the act requiring such approval, except as provided in paragraph (b) of this section. Such a regulation under section 515(b) of the act shall not be effective during the grace period ending on the 90th day after its promulgation or on the last day of the 30th full calendar month after the regulation that classifies the device into class III is effective, whichever is later. See section 501(f)(2)(B) of the act. Accordingly, unless an effective date of the requirement for premarket approval is shown in the regulation for a device classified into class III in this part, the device may be commercially distributed without FDA's issuance of an order approving a PMA or declaring completed a PDP for the device. If FDA promulgates a regulation under section 515(b) of the act requiring premarket approval for a device, section 501(f)(1)(A) of the act applies to the device. (b) Any new, not substantially equivalent, device introduced into commercial distribution on or after May 28, 1976, including a device formerly marketed that has been substantially altered, is classified by statute (section 513(f) of the act) into class III without any grace period and FDA must have issued an order approving a PM… | |||
| 21:21:8.0.1.1.19.1.1.3 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | A | Subpart A—General Provisions | § 864.9 Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). | FDA | [65 FR 2310, Jan. 14, 2000] | The exemption from the requirement of premarket notification (section 510(k) of the act) for a generic type of class I or II device is only to the extent that the device has existing or reasonably foreseeable characteristics of commercially distributed devices within that generic type or, in the case of in vitro diagnostic devices, only to the extent that misdiagnosis as a result of using the device would not be associated with high morbidity or mortality. Accordingly, manufacturers of any commercially distributed class I or II device for which FDA has granted an exemption from the requirement of premarket notification must still submit a premarket notification to FDA before introducing or delivering for introduction into interstate commerce for commercial distribution the device when: (a) The device is intended for a use different from the intended use of a legally marketed device in that generic type of device; e.g., the device is intended for a different medical purpose, or the device is intended for lay use where the former intended use was by health care professionals only; (b) The modified device operates using a different fundamental scientific technology than a legally marketed device in that generic type of device; e.g., a surgical instrument cuts tissue with a laser beam rather than with a sharpened metal blade, or an in vitro diagnostic device detects or identifies infectious agents by using deoxyribonucleic acid (DNA) probe or nucleic acid hybridization technology rather than culture or immunoassay technology; or (c) The device is an in vitro device that is intended: (1) For use in the diagnosis, monitoring, or screening of neoplastic diseases with the exception of immunohistochemical devices; (2) For use in screening or diagnosis of familial or acquired genetic disorders, including inborn errors of metabolism; (3) For measuring an analyte that serves as a surrogate marker for screening, diagnosis, or monitoring life-threatening diseases such as acquired immune deficiency syndrome (AIDS), chroni… | |||
| 21:21:8.0.1.1.19.10.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9050 Blood bank supplies. | FDA | [45 FR 60638, Sept. 12, 1980, as amended at 53 FR 11253, Apr. 6, 1988] | (a) Identification. Blood bank supplies are general purpose devices intended for in vitro use in blood banking. This generic type of device includes products such as blood bank pipettes, blood grouping slides, blood typing tubes, blood typing racks, and cold packs for antisera reagents. The device does not include articles that are licensed by the Center for Biologics Evaluation and Research of the Food and Drug Administration. (b) Classification. Class I (general controls). | |||
| 21:21:8.0.1.1.19.10.1.10 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9195 Blood mixing devices and blood weighing devices. | FDA | [45 FR 60642, Sept. 12, 1980, as amended at 65 FR 2310, Jan. 14, 2000] | (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or blood components by agitation. A blood weighing device is a device intended for medical purposes that is used to weigh blood or blood components as they are collected. (b) Classification. Class I (general controls). The manual device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.11 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9205 Blood and plasma warming device. | FDA | [45 FR 60642, Sept. 12, 1980, as amended at 52 FR 17733, May 11, 1987] | (a) Nonelectromagnetic blood or plasma warming device —(1) Identification. A nonelectromagnetic blood and plasma warming device is a device that warms blood or plasma, by means other than electromagnetic radiation, prior to administration. (2) Classification. Class II (performance standards). (b) Electromagnetic blood and plasma warming device —(1) Identification. An electromagnetic blood and plasma warming device is a device that employs electromagnetic radiation (radiowaves or microwaves) to warm a bag or bottle of blood or plasma prior to administration. (2) Classfication. Class III (premarket approval). (c) Date PMA or notice of completion of a PDP is required. No effective date has been established of the requirement for premarket approval for the device described in paragraph (b)(1). See § 864.3. | |||
| 21:21:8.0.1.1.19.10.1.12 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9225 Cell-freezing apparatus and reagents for in vitro diagnostic use. | FDA | [45 FR 60643, Sept. 12, 1980, as amended at 65 FR 2310, Jan. 14, 2000] | (a) Identification. Cell-freezing apparatus and reagents for in vitro diagnostic use are devices used to freeze human red blood cells for in vitro diagnostic use. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.13 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9245 Automated blood cell separator. | FDA | [72 FR 67644, Nov. 30, 2007] | (a) Identification. An automated blood cell separator is a device that uses a centrifugal or filtration separation principle to automatically withdraw whole blood from a donor, separate the whole blood into blood components, collect one or more of the blood components, and return to the donor the remainder of the whole blood and blood components. The automated blood cell separator device is intended for routine collection of blood and blood components for transfusion or further manufacturing use. (b) Classification. Class II (special controls). The special control for this device is a guidance for industry and FDA staff entitled “Class II Special Controls Guidance Document: Automated Blood Cell Separator Device Operating by Centrifugal or Filtration Separation Principle.” | |||
| 21:21:8.0.1.1.19.10.1.14 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9275 Blood bank centrifuge for in vitro diagnostic use. | FDA | [45 FR 60645, Sept. 12, 1980, as amended at 65 FR 2310, Jan. 14, 2000] | (a) Identification. A blood bank centrifuge for in vitro diagnostic use is a device used only to separate blood cells for further diagnostic testing. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.15 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9285 Automated cell-washing centrifuge for immuno-hematology. | FDA | [45 FR 60646, Sept. 12, 1980] | (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used to separate and prepare cells and sera for further in vitro diagnostic testing. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.10.1.16 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9300 Automated Coombs test systems. | FDA | [45 FR 60646, Sept. 12, 1980] | (a) Identification. An automated Coombs test system is a device used to detect and identify antibodies in patient sera or antibodies bound to red cells. The Coombs test is used for the diagnosis of hemolytic disease of the newborn, and autoimmune hemolytic anemia. The test is also used in crossmatching and in investigating transfusion reactions and drug-induced red cell sensitization. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.10.1.17 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9320 Copper sulfate solution for specific gravity determinations. | FDA | [45 FR 60647, Sept. 12, 1980, as amended at 65 FR 2310, Jan. 14, 2000] | (a) Identification. A copper sulfate solution for specific gravity determinations is a device used to determine whether the hemoglobin content of a potential donor's blood meets the required level (12.5 grams per 100 milliliters of blood for women and 13.5 grams per 100 milliliters of blood for men). (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.18 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9400 Stabilized enzyme solution. | FDA | [45 FR 60647, Sept. 12, 1980, as amended at 84 FR 71800, Dec. 30, 2019] | (a) Identification. A stabilized enzyme solution is a reagent intended for medical purposes that is used to enhance the reactivity of red blood cells with certain antibodies, including antibodies that are not detectable by other techniques. These enzyme solutions include papain, bromelin, ficin, and trypsin. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.19 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9550 Lectins and protectins. | FDA | [45 FR 60648, Sept. 12, 1980, as amended at 63 FR 59226, Nov. 3, 1998] | (a) Identification. Lectins and protectins are proteins derived from plants and lower animals that cause cell agglutination in the presence of certain antigens. These substances are used to detect blood group antigens for in vitro diagnostic purposes. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9100 Empty container for the collection and processing of blood and blood components. | FDA | [45 FR 60638, Sept. 12, 1980] | (a) Identification. An empty container for the collection and processing of blood and blood components is a device intended for medical purposes that is an empty plastic bag or plastic or glass bottle used to collect, store, or transfer blood and blood components for further processing. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.10.1.20 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9575 Environmental chamber for storage of platelet concentrate. | FDA | [45 FR 60648, Sept. 12, 1980, as amended at 63 FR 59226, Nov. 3, 1998] | (a) Identification. An environmental chamber for storage of platelet concentrate is a device used to hold platelet-rich plasma within a preselected temperature range. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.21 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9600 Potentiating media for in vitro diagnostic use. | FDA | [45 FR 60649, Sept. 12, 1980, as amended at 63 FR 59226, Nov. 3, 1998] | (a) Identification. Potentiating media for in vitro diagnostic use are media, such as bovine albumin, that are used to suspend red cells and to enhance cell reactions for antigen-antibody testing. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.22 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9650 Quality control kit for blood banking reagents. | FDA | [45 FR 60649, Sept. 12, 1980] | (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells, buffers, and antibodies used to determine the specificity, potency, and reactivity of the cells and reagents used for blood banking. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.10.1.23 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9700 Blood storage refrigerator and blood storage freezer. | FDA | [45 FR 60650, Sept. 12, 1980, as amended at 63 FR 59226, Nov. 3, 1998] | (a) Identification. A blood storage refrigerator and a blood storage freezer are devices intended for medical purposes that are used to preserve blood and blood products by storing them at cold or freezing temperatures. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.24 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9750 Heat-sealing device. | FDA | [45 FR 60650, Sept. 12, 1980, as amended at 65 FR 2311, Jan. 14, 2000] | (a) Identification. A heat-sealing device is a device intended for medical purposes that uses heat to seal plastic bags containing blood or blood components. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.25 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9875 Transfer set. | FDA | [45 FR 60651, Sept. 12, 1980] | (a) Identification. A transfer set is a device intended for medical purposes that consists of a piece of tubing with suitable adaptors used to transfer blood or plasma from one container to another. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.10.1.3 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9115 Container system for the processing and storage of Red Blood Cell components under reduced oxygen conditions. | FDA | [88 FR 77199, Nov. 9, 2023] | (a) Identification. A container system for the processing and storage of Red Blood Cell components under reduced oxygen conditions is a device intended for medical purposes that is used to process and store Red Blood Cell components and reduce oxygen levels in the storage environment. (b) Classification. Class II (special controls). The special controls for this device are: (1) The intended use of the device must specify: (i) The Red Blood Cell components that can be processed and stored including acceptable anticoagulants and additive solutions; (ii) The hold time after Red Blood Cell component collection; (iii) The processing capacity (volume) of the device; and (iv) The storage temperature and dating period of processed Red Blood Cell components. (2) Studies must demonstrate that the device is biocompatible and include detailed documentation of the biocompatibility evaluation. (3) Performance testing and nonclinical studies must include a detailed study of leached materials extracted under conditions similar to clinical usage of the device, and a toxicologic risk assessment of those extracted or leached materials. (4) Performance testing must support sterility of the device and include sterilization validation, endotoxin testing, and container closure integrity evaluation. (5) Nonclinical and clinical studies must include evaluation of red blood cell quality throughout the duration of storage based on in vitro and in vivo studies, including hemolysis and red blood cell survival and recovery. (6) Performance studies must include: (i) Detailed documentation of functional and mechanical testing, including evaluation of oxygen and, if applicable, carbon dioxide levels during Red Blood Cell components storage; and (ii) Detailed documentation of device shelf-life testing demonstrating continued sterility, package integrity, and functionality over the identified shelf life. (7) The labeling must include a contraindication against processing Red Blood Cell components collected from donors with hemogl… | |||
| 21:21:8.0.1.1.19.10.1.4 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9125 Vacuum-assisted blood collection system. | FDA | [45 FR 60639, Sept. 12, 1980, as amended at 65 FR 2310, Jan. 14, 2000] | (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to draw blood for subsequent reinfusion. (b) Classification. Class I (general controls). The manual device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.5 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9145 Processing system for frozen blood. | FDA | [45 FR 60639, Sept. 12, 1980] | (a) Identification. A processing system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize hemolysis (disruption of the red cell membrane accompanied by the release of hemoglobin) due to freezing and thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.10.1.6 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9160 Blood group substances of nonhuman origin for in vitro diagnostic use. | FDA | [45 FR 60640, Sept. 12, 1980, as amended at 53 FR 11253, Apr. 6, 1988; 63 FR 59225, Nov. 3, 1998] | (a) Identification. Blood group substances of nonhuman origin for in vitro diagnostic use are materials, such as blood group specific substances prepared from nonhuman sources (e.g., pigs, cows, and horses) used to detect, identify, or neutralize antibodies to various human blood group antigens. This generic type of device does not include materials that are licensed by the Center for Biologics Evaluation and Research of the Food and Drug Administration. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.10.1.7 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9165 Blood establishment computer software and accessories. | FDA | [83 FR 23217, June 18, 2018] | (a) Identification. Blood establishment computer software (BECS) is a device used in the manufacture of blood and blood components to assist in the prevention of disease in humans by identifying ineligible donors, by preventing the release of unsuitable blood and blood components for transfusion or for further manufacturing into products for human treatment or diagnosis, by performing compatibility testing between donor and recipient, or by performing positive identification of patients and blood components at the point of transfusion to prevent transfusion reactions. This generic type of device may include a BECS accessory, a device intended for use with BECS to augment the performance of the BECS or to expand or modify its indications for use. (b) Classification. Class II (special controls). The special controls for these devices are: (1) Software performance and functional requirements including detailed design specifications ( e.g., algorithms or control characteristics, alarms, device limitations, and safety requirements). (2) Verification and validation testing and hazard analysis must be performed. (3) Labeling must include: (i) Software limitations; (ii) Unresolved anomalies, annotated with an explanation of the impact on safety or effectiveness; (iii) Revision history; and (iv) Hardware and peripheral specifications. (4) Traceability matrix must be performed. (5) Performance testing to ensure the safety and effectiveness of the system must be performed, including when adding new functional requirements ( e.g., electrical safety, electromagnetic compatibility, or wireless coexistence). | |||
| 21:21:8.0.1.1.19.10.1.8 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9175 Automated blood grouping and antibody test system. | FDA | [45 FR 60641, Sept. 12, 1980] | (a) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red blood cells) and to detect antibodies to blood group antigens. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.10.1.9 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | J | Subpart J—Products Used In Establishments That Manufacture Blood and Blood Products | § 864.9185 Blood grouping view box. | FDA | [45 FR 60641, Sept. 12, 1980, as amended at 65 FR 2310, Jan. 14, 2000] | (a) Identification. A blood grouping view box is a device with a glass or plastic viewing surface, which may be illuminated and heated, that is used to view cell reactions in antigen-antibody testing. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.11.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | K | Subpart K—Products Used In Establishments That Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) | § 864.9900 Cord blood processing system and storage container. | FDA | [72 FR 4638, Feb. 1, 2007] | (a) Identification. A cord blood processing system and storage container is a device intended for use in the processing and the storage of cord blood. This device is a functionally closed processing system that includes containers, other soft goods, and a centrifugation system for cord blood concentration, and a final container for the cryopreservation and the storage of a cord blood product. (b) Classification. Class II (special controls). The special control for this device is FDA's guidance document entitled “Class II Special Controls Guidance Document: Cord Blood Processing System and Storage Container.” For the availability of this guidance document, see § 864.1(d). | |||
| 21:21:8.0.1.1.19.2.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | B | Subpart B—Biological Stains | § 864.1850 Dye and chemical solution stains. | FDA | [45 FR 60583, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001; 90 FR 55981, Dec. 4, 2025] | (a) Identification. Dye and chemical solution stains for medical purposes are mixtures of synthetic or natural dyes or nondye chemicals in solutions used in staining cells and tissues for diagnostic histopathology, cytopathology, or hematology. (b) Classification. Class I (general controls). These devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. These devices are also exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter. | |||
| 21:21:8.0.1.1.19.2.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | B | Subpart B—Biological Stains | § 864.1860 Immunohistochemistry reagents and kits. | FDA | [63 FR 30142, June 3, 1998] | (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro diagnostic devices consisting of polyclonal or monoclonal antibodies labeled with directions for use and performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for use with flow cytometry devices are not considered IHC's. (b) Classification of immunohistochemistry devices. (1) Class I (general controls). Except as described in paragraphs (b)(2) and (b)(3) of this section, these devices are exempt from the premarket notification requirements in part 807, subpart E of this chapter. This exemption applies to IHC's that provide the pathologist with adjunctive diagnostic information that may be incorporated into the pathologist's report, but that is not ordinarily reported to the clinician as an independent finding. These IHC's are used after the primary diagnosis of tumor (neoplasm) has been made by conventional histopathology using nonimmunologic histochemical stains, such as hematoxylin and eosin. Examples of class I IHC's are differentiation markers that are used as adjunctive tests to subclassify tumors, such as keratin. (2) Class II (special control, guidance document: “FDA Guidance for Submission of Immunohistochemistry Applications to the FDA,” Center for Devices and Radiologic Health, 1998). These IHC's are intended for the detection and/or measurement of certain target analytes in order to provide prognostic or predictive data that are not directly confirmed by routine histopathologic internal and external control specimens. These IHC's provide the pathologist with information that is ordinarily reported as independent diagnostic information to the ordering clinician, and the claims associated with these data are widely accepted and supported by valid scientific evidence. Examples of class II IHC's are those intended for semiquantitative measurement of an analyte, such as hormon… | |||
| 21:21:8.0.1.1.19.2.1.3 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | B | Subpart B—Biological Stains | § 864.1865 Cervical intraepithelial neoplasia (CIN) test system. | FDA | [83 FR 234, Jan. 3, 2018] | (a) Identification. A cervical intraepithelial neoplasia (CIN) test system is a device used to detect a biomarker associated with CIN in human tissues. The device is indicated as an adjunct test and not to be used as a stand-alone device. The test results must be interpreted in the context of the patient's clinical history including, but not limited to, prior and current cervical biopsy results, Papanicolaou (Pap) test results, human papillomavirus (HPV) test results, and morphology on hematoxylin and eosin (H&E) stained sections. This device is not intended to detect the presence of HPV. (b) Classification. Class II (special controls). The special controls for this device are: (1) Premarket notification submissions must include the following information: (i) The indications for use must specify the biomarker that is intended to be identified and its adjunct use ( e.g., adjunct to examination of H&E stained slides) to improve consistency in the diagnosis of CIN. (ii) Summary of professional society recommendations, as applicable. (iii) A detailed device description including: (A) A detailed description of all test components, including all provided reagents and required, but not provided, ancillary reagents. (B) A detailed description of instrumentation and equipment, including illustrations or photographs of non-standard equipment or manuals. (C) If applicable, detailed documentation of the device software, including, but not limited to, stand-alone software applications and hardware-based devices that incorporate software. (D) A detailed description of appropriate positive and negative controls that are recommended or provided. (E) Detailed specifications for sample collection, processing, and storage. (F) A detailed description of methodology and assay procedure. (G) A description of the assay cutoff (the medical decision point between positive and negative) or other relevant criteria that distinguishes positive and negative results, including the rationale for the chosen cutoff or other relev… | |||
| 21:21:8.0.1.1.19.2.1.4 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | B | Subpart B—Biological Stains | § 864.1866 Lynch syndrome test systems. | FDA | [83 FR 8357, Feb. 27, 2018] | (a) Identification. Lynch syndrome test systems are in vitro diagnostic tests for use with tumor tissue to identify previously diagnosed cancer patients at risk for having Lynch syndrome. (b) Classification. Class II (special controls). The special controls for this device are: (1) Premarket notification submissions must include the following information, as appropriate: (i) A detailed description of all test components, including all provided reagents, and required but not provided, ancillary reagents. (ii) A detailed description of instrumentation and equipment, including illustrations or photographs of non-standard equipment or manuals. (iii) Detailed documentation of the device software, including, but not limited to, standalone software applications and hardware-based devices that incorporate software. (iv) A detailed description of quality controls including appropriate positive and negative controls that are recommended or provided. (v) Detailed specifications for sample collection, processing, and storage. (vi) A detailed description of methodology and assay procedure. (vii) A description of the assay cut-off ( i.e., the medical decision point between positive and negative results) or other relevant criteria that distinguishes positive and negative results, or ordinal classes of marker expression, including the rationale for the chosen cut-off or other relevant criteria and results supporting validation of the cut-off. (viii) Detailed specification of the criteria for test result interpretation and reporting. (ix) Detailed information demonstrating the performance characteristics of the device, including: (A) Data from an appropriate study demonstrating clinical accuracy using well-characterized clinical specimens representative of the intended use population ( i.e., concordance to Deoxyribonucleic Acid (DNA) sequencing results of the Lynch syndrome associated genes or method comparison to the predicate device using samples with known alterations in genes representative of Lynch syndrome… | |||
| 21:21:8.0.1.1.19.2.1.5 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | B | Subpart B—Biological Stains | § 864.1870 Early growth response 1 (EGR1) gene fluorescence in-situ hybridization (FISH) test system for specimen characterization. | FDA | [79 FR 52196, Sept. 3, 2014] | (a) Identification. An early growth response 1 (EGR1) gene fluorescence in-situ hybridization (FISH) test system for specimen characterization is a device intended to detect the EGR1 probe target on chromosome 5q in bone marrow specimens from patients with acute myeloid leukemia (AML) or myelodysplastic syndrome (MDS). The assay results are intended to be interpreted only by a qualified pathologist or cytogeneticist. These devices do not include automated systems that directly report results without review and interpretation by a qualified pathologist or cytogeneticist. These devices also do not include any device intended for use to select patient therapy, predict patient response to therapy, or to screen for disease as well as any device with a claim for a particular diagnosis, prognosis, monitoring, or risk assessment. (b) Classification. Class II (special controls). The special controls for this device are: (1) Premarket notification submissions must also include the following information: (i) A detailed description of all probes included in the kit; (ii) Purpose of each probe; (iii) Probe molecular specificity; (iv) Probe specificity; (v) Probe limits; (vi) Probe sensitivity; (vii) Specification of required ancillary reagents, instrumentation, and equipment; (viii) Specification of the specimen collection, processing, storage and slide preparation methods; (ix) Specification of the assay procedure; (x) Specification of control elements that are incorporated into the recommended testing procedures; (xi) Specification of risk mitigation elements: Description of all additional procedures, methods, and practices incorporated into the directions for use that mitigate risks associated with testing; (xii) Specification of the criteria for test result interpretation and reporting; (xiii) Device analytical sensitivity data; (xiv) Device analytical specificity data; (xv) Device reference limit data; (xvi) Device precision/reproducibility data; (xvii) Device stability data to include: (A) Real-t… | |||
| 21:21:8.0.1.1.19.2.1.6 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | B | Subpart B—Biological Stains | § 864.1880 Fluorescence in situ hybridization (FISH)-based detection of chromosomal abnormalities from patients with hematologic malignancies. | FDA | [90 FR 27233, June 26, 2025] | (a) Identification. A fluorescence in situ hybridization (FISH)-based detection of chromosomal abnormalities from patients with hematologic malignancies is used to detect chromosomal abnormalities in human specimens from patients with hematologic malignancies. The test is indicated for the clinical management of patients consistent with internationally accepted guidelines ( e.g., World Health Organization guidelines for Classification of Tumours of Haematopoietic and Lymphoid Tissues) and in conjunction with other clinical and clinicopathological criteria. The results are to be interpreted by a pathologist or equivalent professional. (b) Classification. Class II (special controls). The special controls for this device are: (1) Design verification and validation must include: (i) A detailed description of all probes included in the kit; (ii) Purpose of each probe; (iii) Probe molecular specificity; (iv) Probe specificity; (v) Probe limits; (vi) Probe sensitivity; (vii) Specification of required ancillary reagents, instrumentation, and equipment; (viii) Specification of the specimen collection, processing, storage and slide preparation methods; (ix) Specification of the assay procedure; (x) Specification of control elements that are incorporated into the recommended testing procedures; (xi) Specification of the criteria for test result interpretation and reporting; (xii) Documentation demonstrating analytical validation that includes: (A) Device analytical sensitivity data with a minimum of 25 specimens from karyotypically normal males. (B) Device analytical specificity data with a minimum of five specimens from karyotypically normal males. (C) Description of how the clinical threshold was assigned and verification of the assigned clinical threshold. (D) Device precision/reproducibility data with a minimum of six clinical specimens including two negative specimens, two positive specimens near the clinical decision threshold (cut-off) and two positive specimens. The data must include results o… | |||
| 21:21:8.0.1.1.19.3.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | C | Subpart C—Cell And Tissue Culture Products | § 864.2220 Synthetic cell and tissue culture media and components. | FDA | [45 FR 60583, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 27024, May 16, 2001; 66 FR 38789, July 25, 2001] | (a) Identification. Synthetic cell and tissue culture media and components are substances that are composed entirely of defined components (e.g., amino acids, vitamins, inorganic salts) that are essential for the survival and development of cell lines of humans and other animals. This does not include tissue culture media for human ex vivo tissue and cell culture processing applications as described in § 876.5885 of this chapter. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.3.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | C | Subpart C—Cell And Tissue Culture Products | § 864.2240 Cell and tissue culture supplies and equipment. | FDA | [45 FR 60584, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001; 90 FR 55981, Dec. 4, 2025] | (a) Identification. Cell and tissue culture supplies and equipment are devices that are used to examine, propagate, nourish, or grow cells and tissue cultures. These include such articles as slide culture chambers, perfusion and roller apparatus, cell culture suspension systems, and tissue culture flasks, disks, tubes, and roller bottles. (b) Classification. Class I (general controls). These devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. If the devices are not labeled or otherwise represented as sterile, they are exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter. | |||
| 21:21:8.0.1.1.19.3.1.3 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | C | Subpart C—Cell And Tissue Culture Products | § 864.2260 Chromosome culture kit. | FDA | [45 FR 60585, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. A chromosome culture kit is a device containing the necessary ingredients (e.g., Minimum Essential Media (MEM) of McCoy's 5A culture media, phytohemagglutinin, fetal calf serum, antibiotics, and heparin) used to culture tissues for diagnosis of congenital chromosome abnormalities. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.3.1.4 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | C | Subpart C—Cell And Tissue Culture Products | § 864.2280 Cultured animal and human cells. | FDA | [45 FR 60585, Sept. 12, 1980, as amended at 65 FR 2310, Jan. 14, 2000] | (a) Identification. Cultured animal and human cells are in vitro cultivated cell lines from the tissue of humans or other animals which are used in various diagnostic procedures, particularly diagnostic virology and cytogenetic studies. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.3.1.5 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | C | Subpart C—Cell And Tissue Culture Products | § 864.2360 Mycoplasma detection media and components. | FDA | [45 FR 60586, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. Mycoplasma detection media and components are used to detect and isolate mycoplasma pleuropneumonia-like organisms (PPLO), a common microbial contaminant in cell cultures. (b) Classification. Class I (general controls). These devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.3.1.6 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | C | Subpart C—Cell And Tissue Culture Products | § 864.2800 Animal and human sera. | FDA | [45 FR 60586, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. Animal and human sera are biological products, obtained from the blood of humans or other animals, that provide the necessary growth-promoting nutrients in a cell culture system. (b) Classification. Class I (general controls). These devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.3.1.7 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | C | Subpart C—Cell And Tissue Culture Products | § 864.2875 Balanced salt solutions or formulations. | FDA | [45 FR 60586, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. A balanced salt solution or formulation is a defined mixture of salts and glucose in a simple medium. This device is included as a necessary component of most cell culture systems. This media component controls for pH, osmotic pressure, energy source, and inorganic ions. (b) Classification. Class I (general controls). These devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.4.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3010 Tissue processing equipment. | FDA | [45 FR 60587, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001; 90 FR 55981, Dec. 4, 2025] | (a) Identification. Tissue processing equipment consists of devices used to prepare human tissue specimens for diagnostic histological examination by processing specimens through the various stages of decalcifying, infiltrating, sectioning, and mounting on microscope slides. (b) Classification. Class I (general controls). These devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. The devices are also exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter. | |||
| 21:21:8.0.1.1.19.4.1.10 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3875 Automated tissue processor. | FDA | [45 FR 60591, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. An automated tissue processor is an automated system used to process tissue specimens for examination through fixation, dehydration, and infiltration. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.4.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3250 Specimen transport and storage container. | FDA | [54 FR 47206, Nov. 13, 1989, as amended at 65 FR 2310, Jan. 14, 2000; 65 FR 18234, Apr. 7, 2000; 90 FR 55981, Dec. 4, 2025] | (a) Identification. A specimen transport and storage container, which may be empty or prefilled, is a device intended to contain biological specimens, body waste, or body exudate during storage and transport in order that the matter contained therein can be destroyed or used effectively for diagnostic examination. If prefilled, the device contains a fixative solution or other general purpose reagent to preserve the condition of a biological specimen added to the container. This section does not apply to specimen transport and storage containers that are intended for use as part of an over-the-counter test sample collection system for drugs of abuse testing. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter. | |||
| 21:21:8.0.1.1.19.4.1.3 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3260 OTC test sample collection systems for drugs of abuse testing. | FDA | [65 FR 18234, Apr. 7, 2000, as amended at 90 FR 55981, Dec. 4, 2025] | (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device intended to: Collect biological specimens (such as hair, urine, sweat, or saliva), outside of a medical setting and not on order of a health care professional (e.g., in the home, insurance, sports, or workplace setting); maintain the integrity of such specimens during storage and transport in order that the matter contained therein can be tested in a laboratory for the presence of drugs of abuse or their metabolites; and provide access to test results and counseling. This section does not apply to collection, transport, or laboratory testing of biological specimens for the presence of drugs of abuse or their metabolites that is performed to develop evidence for law enforcement purposes. (b) Classification. Class I (general controls). The device is exempt from the premarket notification requirements in part 807, subpart E of this chapter subject to the limitations in § 864.9 if it is sold, distributed, and used in accordance with the restrictions set forth in § 809.40 of this chapter. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning complaint files under § 820.35(a) of this chapter. | |||
| 21:21:8.0.1.1.19.4.1.4 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3300 Cytocentrifuge. | FDA | [45 FR 60588, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. A cytocentrifuge is a centrifuge used to concentrate cells from biological cell suspensions (e.g., cerebrospinal fluid) and to deposit these cells on a glass microscope slide for cytological examination. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.4.1.5 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3400 Device for sealing microsections. | FDA | [45 FR 60589, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. A device for sealing microsections is an automated instrument used to seal stained cells and microsections for histological and cytological examination. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.4.1.6 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3600 Microscopes and accessories. | FDA | [45 FR 60590, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001;90 FR 55981, Dec. 4, 2025 ] | (a) Identification. Microscopes and accessories are optical instruments used to enlarge images of specimens, preparations, and cultures for medical purposes. Variations of microscopes and accessories (through a change in the light source) used for medical purposes include the following: (1) Phase contrast microscopes, which permit visualization of unstained preparations by altering the phase relationship of light that passes around the object and through the object. (2) Fluorescense microscopes, which permit examination of specimens stained with fluorochromes that fluoresce under ultraviolet light. (3) Inverted stage microscopes, which permit examination of tissue cultures or other biological specimens contained in bottles or tubes with the light source mounted above the specimen. (b) Classification. Class I (general controls). These devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter. | |||
| 21:21:8.0.1.1.19.4.1.7 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3700 Whole slide imaging system. | FDA | [83 FR 22, Jan. 2, 2018] | (a) Identification. The whole slide imaging system is an automated digital slide creation, viewing, and management system intended as an aid to the pathologist to review and interpret digital images of surgical pathology slides. The system generates digital images that would otherwise be appropriate for manual visualization by conventional light microscopy. (b) Classification. Class II (special controls). The special controls for this device are: (1) Premarket notification submissions must include the following information: (i) The indications for use must specify the tissue specimen that is intended to be used with the whole slide imaging system and the components of the system. (ii) A detailed description of the device and bench testing results at the component level, including for the following, as appropriate: (A) Slide feeder; (B) Light source; (C) Imaging optics; (D) Mechanical scanner movement; (E) Digital imaging sensor; (F) Image processing software; (G) Image composition techniques; (H) Image file formats; (I) Image review manipulation software; (J) Computer environment; and (K) Display system. (iii) Detailed bench testing and results at the system level, including for the following, as appropriate: (A) Color reproducibility; (B) Spatial resolution; (C) Focusing test; (D) Whole slide tissue coverage; (E) Stitching error; and (F) Turnaround time. (iv) Detailed information demonstrating the performance characteristics of the device, including, as appropriate: (A) Precision to evaluate intra-system and inter-system precision using a comprehensive set of clinical specimens with defined, clinically relevant histologic features from various organ systems and diseases. Multiple whole slide imaging systems, multiple sites, and multiple readers must be included. (B) Reproducibility data to evaluate inter-site variability using a comprehensive set of clinical specimens with defined, clinically relevant histologic features from various organ systems and diseases. Multiple whole slide i… | |||
| 21:21:8.0.1.1.19.4.1.8 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3750 Software algorithm device to assist users in digital pathology. | FDA | [88 FR 7009, Feb. 2, 2023] | (a) Identification. A software algorithm device to assist users in digital pathology is an in vitro diagnostic device intended to evaluate acquired scanned pathology whole slide images. The device uses software algorithms to provide information to the user about presence, location, and characteristics of areas of the image with clinical implications. Information from this device is intended to assist the user in determining a pathology diagnosis. (b) Classification. Class II (special controls). The special controls for this device are: (1) The intended use on the device's label and labeling required under § 809.10 of this chapter must include: (i) Specimen type; (ii) Information on the device input(s) ( e.g., scanned whole slide images (WSI), etc.); (iii) Information on the device output(s) ( e.g., format of the information provided by the device to the user that can be used to evaluate the WSI, etc.); (iv) Intended users; (v) Necessary input/output devices ( e.g., WSI scanners, viewing software, etc.); (vi) A limiting statement that addresses use of the device as an adjunct; and (vii) A limiting statement that users should use the device in conjunction with complete standard of care evaluation of the WSI. (2) The labeling required under § 809.10(b) of this chapter must include: (i) A detailed description of the device, including the following: (A) Detailed descriptions of the software device, including the detection/analysis algorithm, software design architecture, interaction with input/output devices, and necessary third-party software; (B) Detailed descriptions of the intended user(s) and recommended training for safe use of the device; and (C) Clear instructions about how to resolve device-related issues ( e.g., cybersecurity or device malfunction issues). (ii) A detailed summary of the performance testing, including test methods, dataset characteristics, results, and a summary of sub-analyses on case distributions stratified by relevant confounders, such as anatomical characteristics,… | |||
| 21:21:8.0.1.1.19.4.1.9 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | D | Subpart D—Pathology Instrumentation and Accessories | § 864.3800 Automated slide stainer. | FDA | [45 FR 60591, Sept. 12, 1980, as amended at 54 FR 25044, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. An automated slide stainer is a device used to stain histology, cytology, and hematology slides for diagnosis. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.5.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | E | Subpart E—Specimen Preparation Reagents | § 864.4010 General purpose reagent. | FDA | [45 FR 60592, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 62 FR 62260, Nov. 21, 1997; 66 FR 38789, July 25, 2001; 90 FR 55981, Dec. 4, 2025] | (a) A general purpose reagent is a chemical reagent that has general laboratory application, that is used to collect, prepare, and examine specimens from the human body for diagnostic purposes, and that is not labeled or otherwise intended for a specific diagnostic application. It may be either an individual substance, or multiple substances reformulated, which, when combined with or used in conjunction with an appropriate analyte specific reagent (ASR) and other general purpose reagents, is part of a diagnostic test procedure or system constituting a finished in vitro diagnostic (IVD) test. General purpose reagents are appropriate for combining with one or more than one ASR in producing such systems and include labware or disposable constituents of tests; but they do not include laboratory machinery, automated or powered systems. General purpose reagents include cytological preservatives, decalcifying reagents, fixative and adhesives, tissue processing reagents, isotonic solutions and pH buffers. Reagents used in tests for more than one individual chemical substance or ligand are general purpose reagents (e.g., Thermus aquaticus (TAQ) polymerase, substrates for enzyme immunoassay (EIA)). (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter. | |||
| 21:21:8.0.1.1.19.5.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | E | Subpart E—Specimen Preparation Reagents | § 864.4020 Analyte specific reagents. | FDA | [62 FR 62260, Nov. 21, 1997] | (a) Identification. Analyte specific reagents (ASR's) are antibodies, both polyclonal and monoclonal, specific receptor proteins, ligands, nucleic acid sequences, and similar reagents which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens. ASR's that otherwise fall within this definition are not within the scope of subpart E of this part when they are sold to: (1) In vitro diagnostic manufacturers; or (2) Organizations that use the reagents to make tests for purposes other than providing diagnostic information to patients and practitioners, e.g., forensic, academic, research, and other nonclinical laboratories. (b) Classification. (1) Class I (general controls). Except as described in paragraphs (b)(2) and (b)(3) of this section, these devices are exempt from the premarket notification requirements in part 807, subpart E of this chapter. (2) Class II (special controls/guidance documents), when the analyte is used in blood banking tests that have been classified as class II devices (e.g., certain cytomegalovirus serological and treponema pallidum nontreponemal test reagents). Guidance Documents: 1. “Specifications for Immunological Testing for Infectious Disease; Approved Guideline,” NCCLS Document I/LA18-A, December 1994. 2. “Assessment of the Clinical Accuracy of Laboratory Tests Using Receiver Operating Characteristic (ROC) Plots; Tentative Guideline,” NCCLS Document KGP10-T, December 1993. 3. “Review Criteria for Assessment of In Vitro Diagnostic Devices for Direct Detection of Mycobacterium spp,” FDA, July 6, 1993, and its “Attachment 1,” February 28, 1994. 4. “Draft Review Criteria for Nucleic Acid Amplification-Based In Vitro Diagnostic Devices for Direct Detection of Infectious Microorganisms,” FDA, July 6, 1993. 5. The Center for Biologics Evaluation and Research, FDA, “Points to Consider in the Manufa… | |||
| 21:21:8.0.1.1.19.5.1.3 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | E | Subpart E—Specimen Preparation Reagents | § 864.4400 Enzyme preparations. | FDA | [45 FR 60592, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 66 FR 38789, July 25, 2001] | (a) Identification. Enzyme preparations are products that are used in the histopathology laboratory for the following purposes: (1) To disaggregate tissues and cells already in established cultures for preparation into subsequent cultures (e.g., trypsin); (2) To disaggregate fluid specimens for cytological examination (e.g., papain for gastric lavage or trypsin for sputum liquefaction); (3) To aid in the selective staining of tissue specimens (e.g., diastase for glycogen determination). (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.6.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5200 Automated cell counter. | FDA | [45 FR 60593, Sept. 12, 1980] | (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These devices may also measure hemoglobin or hematocrit and may also calculate or measure one or more of the red cell indices (the erythrocyte mean corpuscular volume, the mean corpuscular hemoglobin, or the mean corpuscular hemoglobin concentration). These devices may use either an electronic particle counting method or an optical counting method. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.6.1.10 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5600 Automated hematocrit instrument. | FDA | [45 FR 60600, Sept. 12, 1980] | (a) Identification. An automated hematocrit instrument is a fully automated or semi-automated device which may or may not be part of a larger system. This device measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.6.1.11 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5620 Automated hemoglobin system. | FDA | [45 FR 60601, Sept. 12, 1980] | (a) Identification. An automated hemoglobin system is a fully automated or semi-automated device which may or may not be part of a larger system. The generic type of device consists of the reagents, calibrators, controls, and instrumentation used to determine the hemoglobin content of human blood. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.6.1.12 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5680 Automated heparin analyzer. | FDA | [45 FR 60601, Sept. 12, 1980, as amended at 52 FR 17733, May 11, 1987; 58 FR 51571, Oct. 4, 1993] | (a) Identification. An automated heparin analyzer is a device used to determine the heparin level in a blood sample by mixing the sample with protamine (a heparin-neutralizing substance) and determining photometrically the onset of air-activated clotting. The analyzer also determines the amount of protamine necessary to neutralize the heparin in the patient's circulation. (b) Classification. Class II (special controls). | |||
| 21:21:8.0.1.1.19.6.1.13 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5700 Automated platelet aggregation system. | FDA | [45 FR 60602, Sept. 12, 1980] | (a) Identification. An automated platelet aggregation system is a device used to determine changes in platelet shape and platelet aggregation following the addition of an aggregating reagent to a platelet-rich plasma. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.6.1.14 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5800 Automated sedimentation rate device. | FDA | [45 FR 60602, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 66 FR 38790, July 25, 2001] | (a) Identification. An automated sedimentation rate device is an instrument that measures automatically the erythrocyte sedimentation rate in whole blood. Because an increased sedimentation rate indicates tissue damage or inflammation, the erythrocyte sedimentation rate device is useful in monitoring treatment of a disease. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.6.1.15 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5850 Automated slide spinner. | FDA | [45 FR 60603, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 66 FR 38790, July 25, 2001] | (a) Identification. An automated slide spinner is a device that prepares automatically a blood film on a microscope slide using a small amount of peripheral blood (blood circulating in one of the body's extremities, such as the arm). (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.6.1.16 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5950 Blood volume measuring device. | FDA | [45 FR 60603, Sept. 12, 1980] | (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume, and total blood volume. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.6.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5220 Automated differential cell counter. | FDA | [67 FR 1607, Jan. 14, 2002] | (a) Identification. An automated differential cell counter is a device used to identify one or more of the formed elements of the blood. The device may also have the capability to flag, count, or classify immature or abnormal hematopoietic cells of the blood, bone marrow, or other body fluids. These devices may combine an electronic particle counting method, optical method, or a flow cytometric method utilizing monoclonal CD (cluster designation) markers. The device includes accessory CD markers. (b) Classification. Class II (special controls). The special control for this device is the FDA document entitled “Class II Special Controls Guidance Document: Premarket Notifications for Automated Differential Cell Counters for Immature or Abnormal Blood Cells; Final Guidance for Industry and FDA.” | |||
| 21:21:8.0.1.1.19.6.1.3 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5240 Automated blood cell diluting apparatus. | FDA | [45 FR 60596, Sept. 12, 1980, as amended at 65 FR 2310, Jan. 14, 2000] | (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample for further testing. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.6.1.4 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5260 Automated cell-locating device. | FDA | [45 FR 60597, Sept. 12, 1980] | (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and classify each cell according to type. (Peripheral blood is blood circulating in one of the body's extremities, such as the arm.) (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.6.1.5 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5300 Red cell indices device. | FDA | [45 FR 60597, Sept. 12, 1980] | (a) Identification. A red cell indices device, usually part of a larger system, calculates or directly measures the erythrocyte mean corpuscular volume (MCV), the mean corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices are used for the differential diagnosis of anemias. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.6.1.6 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5350 Microsedimentation centrifuge. | FDA | [45 FR 60598, Sept. 12, 1980, as amended at 59 FR 63007, Dec. 7, 1994; 66 FR 38789, July 25, 2001] | (a) Identification. A microsedimentation centrifuge is a device used to sediment red cells for the microsedimentation rate test. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.6.1.7 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5400 Coagulation instrument. | FDA | [45 FR 60598, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. A coagulation instrument is an automated or semiautomated device used to determine the onset of clot formation for in vitro coagulation studies. (b) Classification. Class II (special controls). A fibrometer or coagulation timer intended for use with a coagulation instrument is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.6.1.8 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5425 Multipurpose system for in vitro coagulation studies. | FDA | [45 FR 60599, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated instrument and its associated reagents and controls. The system is used to perform a series of coagulation studies and coagulation factor assays. (b) Classification. Class II (special controls). A control intended for use with a multipurpose system for in vitro coagulation studies is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.6.1.9 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | F | Subpart F—Automated and Semi-Automated Hematology Devices | § 864.5430 Coagulation system for the measurement of whole blood viscoelastic properties in perioperative patients. | FDA | [90 FR 19630, May 9, 2025] | (a) Identification. A coagulation system for the measurement of whole blood viscoelastic properties in perioperative patients is an in vitro diagnostic device used to evaluate blood coagulation, fibrinolysis, or both, in perioperative patients, as an aid in the assessment of coagulopathies when used in conjunction with clinical signs and symptoms and other clinical and laboratory findings. (b) Classification. Class II (special controls). The special controls for this device are: (1) Design verification and validation must include detailed documentation of, and results from, the following: (i) A study assessing precision using protocols determined to be acceptable by FDA, to cover the measurement range for each reported parameter (test output). Testing must include native specimens with coagulation profiles representative of the intended use population. In order to cover the measuring range, testing may include a limited number of contrived specimens, not to exceed 10 to 20 percent, or as otherwise deemed appropriate by FDA. The contrived specimens must be prepared to resemble clinical specimens. This testing must evaluate repeatability and reproducibility and provide assessments of within-run, within-day, between-run, between-day, between-reagent lot, between-instrument, between-site, and between-operator precision, as applicable to the system; (ii) Studies that demonstrate the performance of each parameter (test output) throughout the claimed measurement range, to include linearity studies or dose-response studies, as applicable to the parameter (test output); (iii) Potential interferent study that includes evaluation of hemolyzed and lipemic samples as potential interferents; exogenous and endogenous interferents associated with each patient population intended for use with the device, and which might be expected to affect assay performance, must be evaluated; and potential interferents that are specific for, or related to, the technology or methodology of the device. Evaluation of all potential interf… | |||
| 21:21:8.0.1.1.19.7.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6100 Bleeding time device. | FDA | [45 FR 60604, Sept. 12, 1980, as amended at 63 FR 59225, Nov. 3, 1998] | (a) Identification. A bleeding time device is a device, usually employing two spring-loaded blades, that produces two small incisions in the patient's skin. The length of time required for the bleeding to stop is a measure of the effectiveness of the coagulation system, primarily the platelets. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.7.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6150 Capillary blood collection tube. | FDA | [45 FR 60604, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 65 FR 2310, Jan. 14, 2000] | (a) Identification. A capillary blood collection tube is a plain or heparinized glass tube of very small diameter used to collect blood by capillary action. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.7.1.3 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6160 Manual blood cell counting device. | FDA | [45 FR 60605, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 66 FR 38790, July 25, 2001] | (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.7.1.4 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6400 Hematocrit measuring device. | FDA | [45 FR 60606, Sept. 12, 1980, as amended at 63 FR 59225, Nov. 3, 1998] | (a) Identification. A hematocrit measuring device is a system consisting of instruments, tubes, racks, and a sealer and a holder. The device is used to measure the packed red cell volume in blood to determine whether the patient's total red cell volume is normal or abnormal. Abnormal states include anemia (an abnormally low total red cell volume) and erythrocytosis (an abnormally high total red cell mass). The packed red cell volume is produced by centrifuging a given volume of blood. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 864.9. | |||
| 21:21:8.0.1.1.19.7.1.5 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6550 Occult blood test. | FDA | [45 FR 60606, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood is blood present in such small quantities that it can be detected only by chemical tests of suspected material, or by microscopic or spectroscopic examination.) (b) Classification. Class II (special controls). A control intended for use with an occult blood test is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.7.1.6 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6600 Osmotic fragility test. | FDA | [45 FR 60607, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 66 FR 38790, July 25, 2001] | (a) Identification. An osmotic fragility test is a device used to determine the resistance of red blood cells to hemolysis (destruction) in varying concentrations of hypotonic saline solutions. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.7.1.7 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6650 Platelet adhesion test. | FDA | [45 FR 60608, Sept. 12, 1980] | (a) Identification. A platelet adhesion test is a device used to determine in vitro platelet function. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.7.1.8 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6675 Platelet aggregometer. | FDA | [45 FR 60608, Sept. 12, 1980] | (a) Identification. A platelet aggregometer is a device, used to determine changes in platelet shape and platelet aggregation following the addition of an aggregating reagent to a platelet rich plasma. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.7.1.9 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | G | Subpart G—Manual Hematology Devices | § 864.6700 Erythrocyte sedimentation rate test. | FDA | [45 FR 60608, Sept. 12, 1980, as amended at 54 FR 25045, June 12, 1989; 66 FR 38790, July 25, 2001] | (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a device that measures the degree of sedimentation taking place in a given length of time. An increased rate indicates tissue damage or inflammation. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.1 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7010 Flow cytometric test system for hematopoietic neoplasms. | FDA | [82 FR 61165, Dec. 27, 2017, as amended at 90 FR 55981, Dec. 4, 2025] | (a) Identification. A flow cytometric test for hematopoietic neoplasms is a device that consists of reagents for immunophenotyping of human cells in relation to the level of expression, antigen density, and distribution of specific cellular markers. These reagents are used as an aid in the differential diagnosis or monitoring of hematologically abnormal patients having or suspected of having hematopoietic neoplasms. The results should be interpreted by a pathologist or equivalent professional in conjunction with other clinical and laboratory findings. (b) Classification. Class II (special controls). The special controls for this device are: (1) Premarket notification submissions must include the following information: (i) The indications for use must indicate the clinical hematopoietic neoplasms for which the assay was designed and validated, for example, chronic leukemia or lymphoma. (ii) A detailed device description including the following: (A) A detailed description of all test components, all required reagents, and all instrumentation and equipment, including illustrations or photographs of nonstandard equipment or methods. (B) Detailed documentation of the device software including, but not limited to, standalone software applications and hardware-based devices that incorporate software. (C) A detailed description of methodology and assay procedure. (D) A description of appropriate internal and external quality control materials that are recommended or provided. The description must identify those control elements that are incorporated into the testing procedure, if applicable. (E) Detailed specifications for sample collection, processing, and storage. (F) Detailed specification of the criteria for test results interpretation and reporting including pre-established templates. (G) If applicable, based on the output of the results, a description of the specific number of events to collect, result outputs, and analytical sensitivity of the assay that will be reported. (iii) Information that dem… | |||
| 21:21:8.0.1.1.19.8.1.10 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7295 Heparin and direct oral factor Xa inhibitor drug test system. | FDA | [89 FR 72317, Sept. 5, 2024] | (a) Identification. A heparin and direct oral factor Xa inhibitor drug test system is intended for the detection of heparin and direct oral factor Xa inhibitors in human specimens collected from patients taking heparin or direct oral factor Xa inhibitors. This device is intended to aid in the management of therapy in conjunction with other clinical and laboratory findings. (b) Classification. Class II (special controls). The special controls for this device are: (1) Design verification and validation must include the following: (i) Detailed documentation of analytical device performance studies and results demonstrating acceptable analytical performance with a sufficient number of specimens tested in order to obtain unbiased estimates of analytical performance. This documentation shall include the following as appropriate to the technology, specimen types tested, and intended use of the device: (A) Studies and results for that demonstrate device precision including repeatability and reproducibility, using quality controls and clinical samples, when appropriate. Precision studies must assess specimens for each indicated drug at concentrations throughout the measuring range of the device including near clinically relevant levels, as appropriate. The study must evaluate different sources of variability including, as appropriate, between-run, between-operator, between-lot, between-instrument, between-day, and between-site; (B) Studies and results that demonstrate that the device is free from clinically significant interference, from endogenous and exogenous interferents associated with the target population(s), and interferents that are specific for, or related to, the technology or methodology of the device; (C) Data to demonstrate appropriate specimen stability for the intended sample matrices under the intended conditions for specimen collection, handling, and storage described in the device labeling; (D) Studies and results that demonstrate the linear range, limit of blank (LoB), limit of detection (Lo… | |||
| 21:21:8.0.1.1.19.8.1.11 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7300 Fibrin monomer paracoagulation test. | FDA | [45 FR 60614, Sept. 12, 1980, as amended at 52 FR 17733, May 11, 1987; 65 FR 17144, Mar. 31, 2000, 84 FR 71799, Dec. 30, 2019] | (a) Identification. A fibrin monomer paracoagulation test is a device used to detect fibrin monomer in the diagnosis of disseminated intravascular coagulation (nonlocalized clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. The special control for this device is FDA's “In Vitro Diagnostic Fibrin Monomer Paracoagulation Test.” See § 864.1(d) for information on obtaining this document. | |||
| 21:21:8.0.1.1.19.8.1.12 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7320 Fibrinogen/fibrin degradation products assay. | FDA | [45 FR 60615, Sept. 12, 1980] | (a) Identification. A fibrinogen/fibrin degradation products assay is a device used to detect and measure fibrinogen degradation products and fibrin degradation products (protein fragments produced by the enzymatic action of plasmin on fibrinogen and fibrin) as an aid in detecting the presence and degree of intravascular coagulation and fibrinolysis (the dissolution of the fibrin in a blood clot) and in monitoring therapy for disseminated intravascular coagulation (nonlocalized clotting in the blood vessels). (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.8.1.13 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7340 Fibrinogen determination system. | FDA | [45 FR 60615, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. A fibrinogen determination system is a device that consists of the instruments, reagents, standards, and controls used to determine the fibrinogen levels in disseminated intravascular coagulation (nonlocalized clotting within the blood vessels) and primary fibrinolysis (the dissolution of fibrin in a blood clot). (b) Classification. Class II (special controls). A control or fibrinogen standard intended for use with a fibrinogen determination system is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.14 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7360 Erythrocytic glucose-6-phosphate dehydrogenase assay. | FDA | [45 FR 60616, Sept. 12, 1980] | (a) Identification. An erythrocytic glucose-6-phosphate dehydrogenase assay is a device used to measure the activity of the enzyme glucose-6-phosphate dehydrogenase or of glucose-6-phosphate dehydrogenase isoenzymes. The results of this assay are used in the diagnosis and treatment of nonspherocytic congenital hemolytic anemia or drug-induced hemolytic anemia associated with a glucose-6-phosphate dehydrogenase deficiency. This generic device includes assays based on fluorescence, electrophoresis, methemoglobin reduction, catalase inhibition, and ultraviolet kinetics. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.8.1.15 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7375 Glutathione reductase assay. | FDA | [45 FR 60616, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. A glutathione reductase assay is a device used to determine the activity of the enzyme glutathione reductase in serum, plasma, or erythrocytes by such techniques as fluorescence and photometry. The results of this assay are used in the diagnosis of liver disease, glutathione reductase deficiency, or riboflavin deficiency. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.16 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7400 Hemoglobin A | FDA | [45 FR 60617, Sept. 12, 1980] | (a) Identification. A hemoglobin A 2 assay is a device used to determine the hemoglobin A 2 content of human blood. The measurement of hemoglobin A 2 is used in the diagnosis of the thalassemias (hereditary hemolytic anemias characterized by decreased synthesis of one or more types of hemoglobin polypeptide chains). (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.8.1.17 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7415 Abnormal hemoglobin assay. | FDA | [45 FR 60618, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. An abnormal hemoglobin assay is a device consisting of the reagents, apparatus, instrumentation, and controls necessary to isolate and identify abnormal genetically determined hemoglobin types. (b) Classification. Class II (special controls). A control intended for use with an abnormal hemoglobin assay is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.18 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7425 Carboxyhemoglobin assay. | FDA | [45 FR 60619, Sept. 12, 1980] | (a) Identification. A carboxyhemoglobin assay is a device used to determine the carboxyhemoglobin (the compound formed when hemoglobin is exposed to carbon monoxide) content of human blood as an aid in the diagnosis of carbon monoxide poisoning. This measurement may be made using methods such as spectroscopy, colorimetry, spectrophotometry, and gasometry. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.8.1.19 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7440 Electrophoretic hemoglobin analysis system. | FDA | [45 FR 60620, Sept. 12, 1980] | (a) Identification. An electrophoretic hemoglobin analysis system is a device that electrophoretically separates and identifies normal and abnormal hemoglobin types as an aid in the diagnosis of anemia or erythrocytosis (increased total red cell mass) due to a hemoglobin abnormality. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.8.1.2 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7040 Adenosine triphosphate release assay. | FDA | [45 FR 60609, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. An adenosine triphosphate release assay is a device that measures the release of adenosine triphosphate (ATP) from platelets following aggregation. This measurement is made on platelet-rich plasma using a photometer and a luminescent firefly extract. Simultaneous measurements of platelet aggregation and ATP release are used to evaluate platelet function disorders. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.20 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7455 Fetal hemoglobin assay. | FDA | [45 FR 60620, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. A fetal hemoglobin assay is a device that is used to determine the presence and distribution of fetal hemoglobin (hemoglobin F) in red cells or to measure the amount of fetal hemoglobin present. The assay may be used to detect fetal red cells in the maternal circulation or to detect the elevated levels of fetal hemoglobin exhibited in cases of hemoglobin abnormalities such as thalassemia (a hereditary hemolytic anemia characterized by a decreased synthesis of one or more types of hemoglobin polypeptide chains). The hemoglobin determination may be made by methods such as electrophoresis, alkali denaturation, column chromatography, or radial immunodiffusion. (b) Classification. Class II (special controls). A fetal hemoglobin stain intended for use with a fetal hemoglobin assay is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.21 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7470 Glycosylated hemoglobin assay. | FDA | [45 FR 60621, Sept. 12, 1980] | (a) Identification. A glycosylated hemoglobin assay is a device used to measure the glycosylated hemoglobins (A 1a , A 1b , and A 1c ) in a patient's blood by a column chromatographic procedure. Measurement of glycosylated hemoglobin is used to assess the level of control of a patient's diabetes and to determine the proper insulin dosage for a patient. Elevated levels of glycosylated hemoglobin indicate uncontrolled diabetes in a patient. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.8.1.22 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7490 Sulfhemoglobin assay. | FDA | [45 FR 60621, Sept. 12, 1980] | (a) Identification. A sulfhemoglobin assay is a device consisting of the reagents, calibrators, controls, and instrumentation used to determine the sulfhemoglobin (a compound of sulfur and hemoglobin) content of human blood as an aid in the diagnosis of sulfhemoglobinemia (presence of sulfhemoglobin in the blood due to drug administration or exposure to a poison). This measurement may be made using methods such as spectroscopy, colorimetry, spectrophotometry, or gasometry. (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.8.1.23 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7500 Whole blood hemoglobin assays. | FDA | [45 FR 60622, Sept. 12, 1980, as amended at 84 FR 71799, Dec. 30, 2019] | (a) Identification. A whole blood hemoglobin assay is a device consisting or reagents, calibrators, controls, or photometric or spectrophotometric instrumentation used to measure the hemoglobin content of whole blood for the detection of anemia. This generic device category does not include automated hemoglobin systems. (b) Classification. Class II (special controls). An acid hematin intended for use with whole blood hemoglobin assays is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.24 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7525 Heparin assay. | FDA | [45 FR 60623, Sept. 12, 1980] | (a) Identification. A heparin assay is a device used to determine the level of the anticoagulant heparin in the patient's circulation. These assays are quantitative clotting time procedures using the effect of heparin on activated coagulation factor X (Stuart factor) or procedures based on the neutralization of heparin by protamine sulfate (a protein that neutralizes heparin). (b) Classification. Class II (performance standards). | |||
| 21:21:8.0.1.1.19.8.1.25 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7660 Leukocyte alkaline phosphatase test. | FDA | [45 FR 60623, Sept. 12, 1980, as amended at 59 FR 63007, Dec. 7, 1994; 66 FR 38790, July 25, 2001] | (a) Identification. A leukocyte alkaline phosphatase test is a device used to identify the enzyme leukocyte alkaline phosphatase in neutrophilic granulocytes (granular leukocytes stainable by neutral dyes). The cytochemical identification of alkaline phosphatase depends on the formation of blue granules in cells containing alkaline phosphatase. The results of this test are used to differentiate chronic granulocytic leukemia (a malignant disease characterized by excessive overgrowth of granulocytes in the bone marrow) and reactions that resemble true leukemia, such as those occuring in severe infections and polycythemia (increased total red cell mass). (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.26 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7675 Leukocyte peroxidase test. | FDA | [45 FR 60624, Sept. 12, 1980, as amended at 59 FR 63007, Dec. 7, 1994; 66 FR 38790, July 25, 2001] | (a) Identification. A leukocyte peroxidase test is a device used to distinguish certain myeloid cells derived from the bone marrow, i.e., neutrophils, eosinophils, and monocytes, from lymphoid cells of the lymphatic system and erythroid cells of the red blood cell series on the basis of their peroxidase activity as evidenced by staining. The results of this test are used in the differential diagnosis of the leukemias. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. | |||
| 21:21:8.0.1.1.19.8.1.27 | 21 | Food and Drugs | I | H | 864 | PART 864—HEMATOLOGY AND PATHOLOGY DEVICES | H | Subpart H—Hematology Kits and Packages | § 864.7695 Platelet factor 4 radioimmunoassay. | FDA | [45 FR 60625, Sept. 12, 1980; 46 FR 14890, Mar. 3, 1981] | (a) Identification. A platelet factor 4 radioimmunoassay is a device used to measure the level of platelet factor 4, a protein released during platelet activation by radioimmunoassay. This device measures platelet activiation, which may indicate a coagulation disorder, such as myocardial infarction or coronary artery disease. (b) Classification. Class II (performance standards). |
Advanced export
JSON shape: default, array, newline-delimited, object
CREATE TABLE cfr_sections (
section_id TEXT PRIMARY KEY,
title_number INTEGER,
title_name TEXT,
chapter TEXT,
subchapter TEXT,
part_number TEXT,
part_name TEXT,
subpart TEXT,
subpart_name TEXT,
section_number TEXT,
section_heading TEXT,
agency TEXT,
authority TEXT,
source_citation TEXT,
amendment_citations TEXT,
full_text TEXT
);
CREATE INDEX idx_cfr_title ON cfr_sections(title_number);
CREATE INDEX idx_cfr_part ON cfr_sections(part_number);
CREATE INDEX idx_cfr_agency ON cfr_sections(agency);